file:///E|/TH-50PHW6BX_TH-50PHW6EX_TH-50PHD6EX_TH-50PHD6BX_TH-50PHD6UY/SVC/s0802000000.html
8.2 Initialization Pulse Adjust
1. Input a Cross hatch signal.
2. Set the picture controls: -
Picture mode: Normal
White balance: Cool
Adjust the indicated test point for the specified wave form.
Test point
Volume
Level
T1 TPSC1 (SC)
---
20 ± 15μ Sec
T2 TPSS1 (SS) R6557 (SC) 155 ± 10μ Sec
file:///E|/TH-50PHW6BX_TH-50PHW6EX_TH-50PHD6EX_TH-50PHD6BX_TH-50PHD6UY/SVC/s0802000000.html (1 z 3) [2006-01-21 10:07:44]