INSTRUCTION MANUAL

Handy Controller Exclusive for 

SF4C 

Series 

SFC-HC

(Ver. 2.0)

Содержание SFC-HC

Страница 1: ... Panasonic Industrial Devices SUNX Co Ltd 2013 MJE SFCHC No 0037 80V FUNCTIO N 㧙 CANCEL ENTER 㧗 INSTRUCTION MANUAL Handy Controller Exclusive for SF4C Series SFC HC Ver 2 0 ...

Страница 2: ...1 Panasonic Industrial Devices SUNX Co Ltd 2013 MJE SFCHC No 0037 80V MEMO ...

Страница 3: ...is device who design a system using this device who install and connect this device who manage and operate a plant using this device 1 Drawings in this instruction manual may be little different with actual product Please be fore warned 2 The contents of this instruction manual may be changed without prior notice for further im provement of the device 3 A part of all of this instruction manual or ...

Страница 4: ...3 1 12 Setting Contents Monitoring Function Only for Ver 2 0 or later of SF4C series 16 3 1 13 Copy Function Only for Ver 2 0 or later of SF4C series 17 3 1 14 Initialization Function 17 3 2 Function Setting Operation Procedure 18 3 2 1 Fixed Blanking Function 20 3 2 2 Floating Blanking Function 21 3 2 3 Auxiliary Output Switching Function 22 3 2 4 Muting Setting Changing Function 23 3 2 5 Overrid...

Страница 5: ...alfunction This device has been developed produced for industrial use only Before using this device check whether the device performs properly with the functions and capa In case of disposal dispose this device as industrial waste User in charge The user in charge has responsible to indicate the person to take the training required for the safety system using method installation operation and main...

Страница 6: ...d stan dard without fail Muting setting changing function The muting setting changing function temporarily invalidates safety function of the connected peripheral devices correctly Failure to do so the operator may suffer a serious injury Environment Do not use a mobile phone or a radio phone near this device Do not use this device in the following environments 1 Areas with high humidity where con...

Страница 7: ...be set in Ver 2 1 of SF4C series only Override setting changing function Muting lamp diagnosis function Safety input setting changing function Invalid setting can be set in only Ver 2 0 or later of SF4C series Large multi purpose indicator setting changing function Interlock setting changing function External device monitor setting changing function Protective function Setting contents monitoring ...

Страница 8: ...er supply of SF4C series once REFERENCE Refer to 3 1 Functional Descriptions for the details of the functions and refer to 3 2 Function Setting Operation Procedure for the setting procedures of the functions respectively 4 Turn OFF the power of emitter and receiver of SF4C series then remove this device 5 Connect both SF4C series and the extension cable with connectors and return the device to the...

Страница 9: ...ame The control output OSSD 1 2 of SF4C series is set to OFF while this device has been con nected Once the setting is completed turn OFF the power remove this device and then turn ON the power again 24V 10 24V 10 For PNP output For NPN output Emitter Receiver Emitter Receiver Shield Blue Brown Orange Orange Black Shield Blue Brown Orange Orange Black Blue Brown Orange Orange Black Connection cabl...

Страница 10: ...m channels receive lights are blocked respectively The all light beam channel can not be selected all valid all invalid G Y SF4C series is not turned OFF even if the particular beam channels are blocked By using a protection structure etc make the dangerous parts of the machine inaccessible to personnel through the sensing area of the particular beam channels G G G the emitter the control output O...

Страница 11: ... 1 2 of SF4C series is turned OFF Continuous mode For use in Europe EU as EN 999 Also applicable to ISO 13855 JIS B 9715 For intrusion direction perpendicular to the sensing area In case that the minimum sensing object is over ø40mm Equation S K T C S Safety distance mm Minimum required distance between the sensing area surface and the dangerous parts of the machine K Intrusion velocity of operato...

Страница 12: ... under unstable light receiving condition Note 1 Note 3 OFF ON Note 3 Note 3 5 ON under unstable light receiving condition Note 1 Note 3 ON OFF Note 3 Note 3 6 ON during muting OFF ON during muting Others OFF OFF 7 OFF during muting ON OFF during muting Others ON ON 8 ON in light receiving condition Note 2 ON OFF OFF 9 OFF in light receiving condition Note 2 OFF ON ON 10 ON during safety input val...

Страница 13: ... Open Normally Open A muting sensor which is to be connected to the muting input 1 ON with light non received status ON with object approaching status and ON with object contacted status A muting sensor which is to be connected to the muting input 2 ON with light non received status ON with object approaching status and ON with object contacted status NONC Normally Open Normally Close A muting sen...

Страница 14: ...end of guard zone shall be under 4 sec Distance between the light curtain and the end of guard zone m S m sec 4 sec 0 2 S The moving speed m sec of the sensing object Note If a beam channel whose muting function is set to be invalid is blocked during the muting the control output OSSD 1 2 will be turned OFF and the muting function will be released Muting input conditions The order for inputting th...

Страница 15: ...ensor NC Normally Closed type Operation at ON state Operation at OFF state Safety con tacting point ON with object non contacted status Emergency stop switch etc PNP output Connect to V NPN output Connect to 0V Open Note Safety sensor ON with light received status Light curtain etc ON with object non approaching status Safety switch etc Note the safety contacting point which is connected to the sa...

Страница 16: ...gray Safety input 2 wire gray black Safety input 1 wire gray Safety input 2 wire gray black Safety con tacting point input mode Connect to V Connect to 0V Connect to V Connect to 0V Safety sensor input mode Connect to V Connect to V Connect to 0V Connect to 0V 3 1 8 Large Multi purpose Indicator Setting Changing Function One mode can be selected from the following 8 modes Factory setting is mode 0...

Страница 17: ...allowed to change without the input of a password of SF4C series When the protective function is set to valid the setting can be changed by inputting the password The setting contents monitor function can be used regardless of the protective function valid invalid The password should be a 4 digit number from 0 to 9 The password of the factory setting is 0000 The protective function is set on the r...

Страница 18: ...on Muting sensor output operation setting NONO Normally Open Normally Open Maximum continuous valid time No limit Muting function only for the sensing object exit Invalid Muting input conditions 1 2 Select beam channel All beam channels Override setting changing function Select function Valid Maximum continuous valid time 60 sec Muting lamp diagnosis function Invalid Safety input setting changing ...

Страница 19: ...g Function To 3 2 5 Override Setting Changing Function To 3 2 6 Muting Lamp Diagnosis Function To 3 2 7 Safety Input Setting Changing Function To 3 2 8 Large Multi purpose Setting Indicator Changing Function To 3 2 14 Initialization Function To 3 2 13 Copy Function Only for Ver 2 0 or later of SF4C series To 3 2 12 Setting Contents Monitoring Function Only for Ver 2 0 or later of SF4C series To 3 ...

Страница 20: ...ord is input you do not need to input the password again till the power is turned OFF Except 3 2 11 Protective Function However if the power is turned ON again without changing the protective function to invalid the password have to be input again since the protective function is still valid The procedure for inputting a password is as follows Input password CH1 Complete inputting password NG ...

Страница 21: ...ottom Emitter Receiver 1 2 3 Beam channel No 1 Fixed blanking function Password Select function Send Check result Send Check result Clear setting Auto setting Valid Invalid Valid Temporary setting Check transmission Check transmission Check setting Check temporary setting Select beam channel Manual setting Setting Valid Invalid 1st beam channel 2nd beam channel Check result Send Check transmission...

Страница 22: ...es setting Valid Non serial beam channel mode Invalid Serial beam channel mode Note Only Ver 2 1 of SF4C series can be set Key operation FUNCTION ENTER CANCEL 2 Floating blanking function Pass word Select beam channel No Invalid Check transmission Send Check result 1 beam channel 2 beam channels 3 beam channels Temporary setting Check setting Check temporary setting Valid Valid Check transmission ...

Страница 23: ...r unstable light receiveing condition Note Mode 5 ON under unstable light receiveing condition Note Mode 6 ON during muting Mode 7 OFF during muting Mode 8 ON in light receiving condition Mode 9 OFF in light receiving condition Mode 10 ON during safety input valid Mode 11 OFF during safety input valid Mode 12 OFF during lockout Mode 13 ON during lockout Key operation FUNCTION ENTER CANCEL 3 Auxili...

Страница 24: ... the sensing object exit Muting input 1 setting 1 Muting input 2 setting 1 Temporary setting Check temporary setting 4 000ms 2 sec 600 sec Order input Y Muting input 1 setting 1 Muting input 2 setting 1 Check temporary setting Check temporary setting Temporary setting Temporary setting Check transmission Send Check setting Check result To p 24 NONO NONC Muting sensor output operation setting Note ...

Страница 25: ... input 1 setting Muting input 2 setting Select beam channel 2 Invalid Valid 1st beam channel 2nd beam channel ຠ ຠ A A NONO NONC 2㸸 Functional setting of each beam channel is as follows Muting function is valid Muting function is invalid Note Only Ver 2 1 of SF4C series can be set No limit 1 sec 2 sec 600 sec 100ms 200ms 4 000ms Invalid To p 25 Order input 1 2 1st beam channel 2nd beam channel Muti...

Страница 26: ...only the beam channel that the muting is valid set to the auto setting in the emission halt condition Key operation FUNCTION ENTER CANCEL Beam channel No The beam channel No is given with 1 2 3 from bottom Emitter Receiver 1 2 3 Beam channel No To p 24 to p 23 Manual setting Order input Y Order input Y Select beam channel 2 1st beam channel 2nd beam channel Beam channel setting 2 Invalid Valid Mut...

Страница 27: ... Setting Changing Function Note The factory setting is 60 sec Key operation FUNCTION ENTER CANCEL 5 Override set ting chang ing function Password Maximum con tinuous valid time 1 sec 2 sec 600 sec 3 sec 600 sec Temporary setting Check temporary setting Check setting Check transmission Send Check result ...

Страница 28: ...0037 80V Function Setting 3 2 6 Muting Lamp Diagnosis Function 6 Muting lamp diagnosis function Password Select function Invalid Valid FUNCTION ENTER CANCEL Temporary setting Check temporary setting Check setting Check transmission Send Check result Key operation ...

Страница 29: ...CTION ENTER CANCEL 7 Safety input setting chang ing function Password Select input mode Input mode for safety sensor Invalid note Key operation Input mode for safety con tacting point Temporary setting Check temporary setting Check setting Check transmission Send Check result Note Only possible to set in Ver 2 0 or later of SF4C series ...

Страница 30: ...urpose indicator input 1 is ON Blinks in red during large multi purpose indicator input 2 is ON Mode 5 Blinks in green during large multi purpose indicator input 1 is ON Lights up in green during large multi purpose indicator input 2 is ON Mode 6 Light up in green during control output OSSD 1 2 is ON Light up in red during control output OSSD 1 2 is OFF Blinks in green during muting Mode 7 Lights ...

Страница 31: ...anging function Password Select mode Mode 0 Mode 1 Mode 2 Mode 3 Setting for inter lock Mode 0 Start Restart interlock is valid Factory setting Mode 1 Start interlock is valid Mode 2 Restart interlock is valid Mode 3 Invalid Key operation FUNCTION ENTER CANCEL Temporary setting Check temporary setting Check setting Check transmission Send Check result ...

Страница 32: ...rnal device monitor function is invalid Valid The external device monitor function is valid The factory setting is 300ms 10 External device monitor setting changing function Password Select function Valid Invalid Time setting 100ms 110ms 120ms 600ms Temporary setting Check temporary setting Check setting Check transmission Send Check result Temporary setting Check temporary setting Check setting C...

Страница 33: ...ord Select function Invalid valid Changing password Change to new password Temporary setting Check temporary setting Check setting Check transmission Send Check result Temporary setting Check temporary setting Check setting Check transmission Send Check result Check result Send Check transmission Check setting Temporary setting Check temporary setting Key operation ...

Страница 34: ...Record 1 Record 5 Summary record Current setting Record 1 Record 5 Detail record Summary record Detail record Valid Invalid Current setting Record 1 Record 5 Valid Valid Invalid Maximum continu ous valid time Muting input conditions Setting for muting function only for the sensing object exit Select function Fixed blanking function Floating blanking function Auxiliary output switching function Mut...

Страница 35: ...CANCEL ᶵ ㄆ ࣔ ࢻ3 ຠ Safety input setting changing function Large multi purpose indicator setting changing function Interlock setting changing function External device monitor setting changing function Protective function Model No No of beam channel Muting lamp diagnosis function to P33 Function Setting ...

Страница 36: ...ater of SF4C series 13 Copy function Password Select function Upload Download Monitor Check function Fixed blanking function Floating blanking function Auxiliary output switching function Check transmission Send Check result Check transmission Send Check result Detail record Valid Valid Invalid Detail record Valid Invalid Invalid ...

Страница 37: ...0 to 600ms in units of 10ms FUNCTION ENTER CANCEL Muting setting changing function Override setting changing function Muting lamp diagnosis function Safety input setting changing function Large multi purpose indicator setting changing function Interlock setting changing function External device monitor setting changing function Protective function Detail record Valid Valid Invalid Check function M...

Страница 38: ...valid time 60 sec Muting lamp diagnosis function Invalid Safety input setting changing function Select function Valid Select input mode Safety contacting point input mode Large multi purpose input function changing function Select mode Mode 0 Lights up in red when large multi purpose indicator input 1 is ON Lights up in green when large multi purpose in dicator input 2 is ON Lockout blinking displ...

Страница 39: ...received condition lights received all lights blocked condition or the muting function in all lights received condition The copy function is used for the units Use the copy function for the units having In the copy function download the data without uploading or select monitor of copy function Upload the data before downloading or se lect monitor of copy function The password does not match Input ...

Страница 40: ...ty input setting changing function Large multi purpose indicator setting changing function Interlock setting changing function External device monitor setting changing function Protective function Setting contents monitoring function Copy function Note Initialization function Protection IP40 Ambient temperature 10 to 55 C No dew condensation or icing allowed Storage 25 to 45 C Ambient humidity 30 ...

Страница 41: ...Panasonic Industrial Devices SUNX Co Ltd 2013 MJE SFCHC No 0037 80V Revision history First edition September 10 2009 Second edition November 20 2009 Third edition April 13 2011 Fourth edition March 1 2013 ...

Страница 42: ...41 Panasonic Industrial Devices SUNX Co Ltd 2013 MJE SFCHC No 0037 80V MEMO ...

Страница 43: ...TED ENTITIES BE LIABLE FOR DAMAGES IN EXCESS OF THE PURCHASE PRICE OF THE PRODUCTS OR FOR ANY INDIRECT INCIDENTAL SPECIAL OR CONSEQUENTIAL DAMAGES OF ANY KIND GENERAL TERMS AND CONDITIONS 4 OR ANY DAMAGES RESULTING FROM LOSS OF USE BUSINESS INTERRUPTION LOSS OF INFORMA TION LOSS OR INACCURACY OF DATA LOSS OF PROFITS LOSS OF SAVINGS THE COST OF PROCUREMENT OF SUBSTITUTED GOODS SERVICES OR TECHNOLOG...

Страница 44: ... id pidsx global 2431 1 Ushiyama cho Kasugai shi Aichi 486 0901 Japan Phone 81 568 33 7861 FAX 81 568 33 8591 About our sale network please visit our website PRINTED IN JAPAN Panasonic Industrial Devices SUNX Co Ltd 2013 ...

Страница 45: ...230 1180 SFB CCB7 F39 LJ1 F39 LJ2 40552 0100 40553 0150 F39 GWUM F39 PTJ F3SJ E0465P25 MS SFD 3 6 SFD CCB7 MU SF4D H8 FF SPS47TRG 120257 0039 120257 0036 120257 0034 120257 0030 120257 0041 120257 0038 120257 0037 120257 0035 120257 0033 120257 0031 120257 0026 120257 0029 120257 0024 120257 0022 120257 0025 120257 0023 120257 0020 120257 0021 120257 0019 120257 0018 120257 0017 120257 0016 120255...