Functions
© Panasonic Industrial Devices SUNX Co., Ltd. 2020
84
5-7-6 Synchronization method and application indication
When application indication is used with line synchronization, the same content is indicated on
the emitter and receiver of the light curtain.
When application indication is used with optical synchronization, different content is indicated
on the emitter and receiver of the light curtain, depending on the light curtain setting.
The table below shows the relationship between synchronization method and indication in re
-
sponse to states of the light curtain.
Application indicator setting
Line synchronization
Optical synchronization
Emitter
Receiver
Emitter
Receiver
Application indicator input 1 / 2
Possible
Possible
Possible (Note 1)
Control output
(OSSD 1 / 2)
ON
Possible
Not possible
Possible
OFF
Possible
Not possible
Possible
Interlock
Possible
Not possible
Possible
Test
Possible
Possible
Possible (Note 2)
Lockout
Possible
Possible
Possible
Muting
Possible
Not possible
Possible (Note 2)
Override
Possible
Not possible
Possible (Note 3)
Notes: 1) When using optical synchronization / application indicator oriented specification / PNP output (5-core
cable) or optical synchronization / application indicator oriented specification / NPN output (5-core
cable), only application indicator input 1 is incorporated.
2) Indication is possible when using optical synchronization / standard specification (12-core cable), optical
synchronization / muting specification / PNP output (12-core cable), or optical synchronization / muting
specification / NPN output (12-core cable).
3) Indication is possible when using optical synchronization / muting specification / PNP output (12-core
cable), or optical synchronization / muting specification / NPN output (12-core cable).
5-7-7 List of indication colors and ON / Blinking settings
Indication methods that can be set for each indication are shown in the table below.
Even if indicated as settable in the table below, the actual indication is based on
chronization method and application indication”
.
Application indicator setting
Indication color selection
ON / Blinking
Blue
Green
Cyan
Red
Magenta Orange
ON
Blinking
Application indicator input 1 / 2
Possible Possible Possible Possible Possible Possible Possible Possible
Control output
(OSSD 1 / 2)
ON
Possible Possible Possible Not pos
-
sible
Possible Possible Possible Not pos
-
sible
OFF
Possible Not pos
-
sible
Possible Possible Possible Possible Possible Not pos
-
sible
Interlock
Possible Possible Possible Possible Possible Possible Possible Not pos
-
sible
Test
Possible Possible Possible Possible Possible Possible Possible Not pos
-
sible
Lockout
Not pos
-
sible
Not pos
-
sible
Not pos
-
sible
Possible Not pos
-
sible
Not pos
-
sible
Not pos
-
sible
Possible
Muting
Possible Possible Possible Possible Possible Possible Possible Possible
Override
Possible Possible Possible Possible Possible Possible Possible Possible
Application indicator input, control output (OSSD 1 / 2), interlock, and test are exclusive selec-
tions and can be set for each light curtain.
Lockout, muting, and override can be selected at the same time as the above settings.
If application indicator inputs 1 / 2 are input at the same time, the indication color will be a mix
-
ture of the selected colors.
Содержание SF4D-TM1
Страница 2: ... Panasonic Industrial Devices SUNX Co Ltd 2020 2 MEMO ...
Страница 26: ...Procedures for Operation Panasonic Industrial Devices SUNX Co Ltd 2020 26 MEMO ...
Страница 50: ...Software Tool Panasonic Industrial Devices SUNX Co Ltd 2020 50 MEMO ...
Страница 89: ... Panasonic Industrial Devices SUNX Co Ltd 2020 89 Chapter 6 Troubleshooting ...