Functions
© Panasonic Industrial Devices SUNX Co., Ltd. 2020
58
●
Wiring example: Line synchronization / standard specification (12-core cable)
<Using NPN output>
K1
K2
+
24V DC
+20
-30
%
-
Gray cable
Gray cable
(with black line)
(Brown) + V
(Brown) + V
(Pale purple) Interlock setting input
(Gray / Black) Application indicator input 2
(Gray) Application indicator input 1
(Pink) Test / Reset input
(Red / White) Muting auxiliary output
(Red) Auxiliary output 1
(Pale blue) Output polarity setting / Lockout release input
(Yellow) Override input
(Pale blue) Output polarity setting / Lockout release input
(Red) Auxiliary output 2
(Gray) NC
(Blue) 0V
(Blue) 0V
(Orange) Synchroni
(Pale purple) External device monitor input
(Black) Control output 1 (OSSD 1)
(Pink) Muting input A
(White) Control output 2 (OSSD 2)
(Yellow) Muting input B
(Orange) Synchroni
(Orange / Black) Synchronization -
(Orange / Black) Synchronization -
*S1
Load
K1 K2
Emitter
Receiver
*Symbols
Switch S1
0 to +2.5V (sink current 5mA or less): Emission halt, Open: Emission
K1, K2: External device (forcible guide relay or magnetic conductor), etc.