CC-LINK Network Communication
WUME-SCHG1C-4
4-28
4-4 Memory map and controller assignments
●
This product can be connected to a maximum of 15 controllers (one master controller, 14 slave
controllers).
●
To enable data communication with connected controllers (master unit and slave units), the
memory map contains a communication register for each controller.
●
The controllers are assigned to register positions in the memory map based on the position
in which each is connected.
The controllers are automatically assigned in the memory map starting from the master unit
and continuing in order from slave unit 1. The order cannot be changed.
Example: Mode 3 remote register RWr
RWr
F
E
D
C
B
A
9
8
7
6
5
4
3
2
1
0
+00 Not used
Command response sensor
Slave
unit 14
Slave
unit 13
Slave
unit 12
Slave
unit 11
Slave
unit 10
Slave
unit 9
Slave
unit 8
Slave
unit 7
Slave
unit 6
Slave
unit 5
Slave
unit 4
Slave
unit 3
Slave
unit 2
Slave
unit 1
Master
unit
+01
Command response code
+02
Sensor response data
Master unit (32 bits)
+03
+04
Sensor response data
Slave unit 1 (32 bits)
+05
+06
Sensor response data
Slave unit 2 (32 bits)
+07
+08
Sensor response data
Slave unit 3 (32 bits)
+09
+0A
Sensor response data
Slave unit 4 (32 bits)
+0B
+0C
Sensor response data
Slave unit 5 (32 bits)
+0D
+0E
Sensor response data
Slave unit 6 (32 bits)
+0F
+10
Sensor response data
Slave unit 7 (32 bits)
+11
+12
Sensor response data
Slave unit 8 (32 bits)
+13
+14
Sensor response data
Slave unit 9 (32 bits)
+15
+16
Sensor response data
Slave unit 10 (32 bits)
+17
+18
Sensor response data
Slave unit 11 (32 bits)
+19
+1A
Sensor response data
Slave unit 12 (32 bits)
+1B
+1C
Sensor response data
Slave unit 13 (32 bits)
+1D
+1E
Sensor response data
Slave unit 14 (32 bits)
+1F
+20
Not used
~
+3F
In the case of Slave 14, the
unit is assigned to the reg-
ister indicated by the arrow.
In the case of the Master unit, the
unit is assigned to the register
indicated by the arrow.
SC-HG1-C
Controller
Slave unit 14
Slave unit 13
Slave unit 12
Slave unit 1
1
Slave unit 10
Slave unit 9
Slave unit 8
Slave unit 7
Slave unit 6
Slave unit 5
Slave unit 4
Slave unit 3
Slave unit 2
Slave unit 1
Master unit
*1: There are other registers in addition to the above example that are assigned in the same way.
that corresponds to the mode you are actually using.
Содержание SC-HG1-C
Страница 2: ...WUME SCHG1C 4 2 MEMO ...
Страница 8: ...WUME SCHG1C 4 8 MEMO ...
Страница 16: ...WUME SCHG1C 4 1 8 MEMO ...
Страница 17: ...2 1 2 System Configuration 2 1 Communication unit system 2 2 2 2 Unit types 2 4 ...
Страница 22: ...WUME SCHG1C 4 2 6 MEMO ...
Страница 106: ...WUME SCHG1C 4 4 72 MEMO ...
Страница 107: ...5 1 5 Specifications 5 1 Specifications 5 2 5 2 Dimensions 5 3 ...
Страница 110: ...WUME SCHG1C 4 5 4 MEMO ...
Страница 111: ...6 1 6 Warranty 6 1 When you purchase and use the product 6 2 ...
Страница 114: ...WUME SCHG1C 4 6 4 MEMO ...
Страница 115: ...7 1 7 Maintenance 7 1 Maintenance and Inspection 7 2 7 1 1 Maintenance cautions 7 2 7 1 2 Main inspection items 7 2 ...
Страница 124: ...WUME SCHG1C 4 8 8 MEMO ...
Страница 125: ...Revision History 1st edition 1 27 2017 2nd edition 9 8 2017 3rd edition 9 30 2019 4th edition 12 1 2019 ...
Страница 126: ... MEMO ...
Страница 127: ... MEMO ...