4
1.2.
Caution for AC Cord (For GS only)
Figure 1-2
1.3.
Before Use (For PH only)
Be sure to disconnect the AC cord before adjusting the voltage selector.
Use a minus(-) screwdriver to set the voltage selector (on the bottom panel) to the voltage setting for the area in which the unit will
be used.
Note
: that this unit will be seriously damaged if this setting is not made correctly. (There is no voltage selector for some countries,
the correct voltage is already set.)
Figure 1-3
1.4.
Before Repair and Adjustment
Caution :
DO NOT SHORT-CIRCUIT DIRECTLY (with a screwdriver blade, for instance), as this may destroy solid state devices.
After repairs are completed, restore power gradually using a variac, to avoid overcurrent.
• Current consumption at AC 220V - 240V, at 50/60Hz during power on, (In Standby mode) should be ~550 mA. (For PR/GS)
• Current consumption at AC 110V - 127V / 220V - 240V, at 50/60Hz during power on, (In Standby mode) should be ~550 mA. (For
PH)