Sound stops during a performance.
The function of this circuitry is to prevent circuitry damage if, for example, the positive and negative speaker connection wires are
“shorted”, or if speaker systems with an impedance less than the indicated rated impedance of the amplifier are used.
If this occurs, follow the procedure outlines below:
1. Turn off the power.
2. Determine the cause of the problem and correct it.
3. Turn on the power once again after one minute.
Note :
When the protection circuitry functions, the unit will not operate unless the power is first turned off and then on again.
3 Safety Precautions
3.1. General Guidelines
1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
2. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
3. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
3.1.1. Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the two prongs on the plug.
2. Measure the resistance value, with an ohmmeter, between the jumpered AC plug and each exposed metallic cabinet part on
the equipment such as screwheads, connectors, control shafts, etc. When the exposed metallic part has a return path to the
chassis, the reading should be between 1M
Ω
and 5.2M
Ω
.
When the exposed metal does not have a return path to the chassis, the reading must be
・
.
Figure 1
3.1.2. Leakage Current Hot Check
(See Figure 1)
1. Plug the AC cord directly into the AC outlet. Do not use an isolation transformer for this check.
2. Connect a 1.5k
Ω
, 10 watts resistor, in parallel with a 0.15µF capacitor, between each exposed metallic part on the set and a
good earth ground such as a water pipe, as shown in Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of the above measurements.
6. The potential at any point should not exceed 0.75 volts RMS. A leakage current tester (Simpson Model 229 or equivalent) may
be used to make the hot checks, leakage current must not exceed 1/2 milliamp. In case a measurement is out of the limits
specified, there is a possibility of a shock hazard, and the equipment should be repaired and rechecked before it is returned to
the customer.
4 Prevention of Electro Static Discharge (ESD) to
Electrostatically Sensitive (ES) Devices
Some semiconductor (solid state) devices can be damaged easily by electricity. Such components commonly are called
Electrostatically Sensitive (ES) Devices. Examples of typical ES devices are integrated circuits and some field-effect transistors and
4
SA-VK61DEE
Содержание SA-VK61
Страница 7: ...Fig 6 2 7 SA VK61DEE ...
Страница 10: ...9 Operation Procedures 10 SA VK61DEE ...
Страница 11: ...11 SA VK61DEE ...
Страница 12: ...10 Disc information 12 SA VK61DEE ...
Страница 13: ...13 SA VK61DEE ...
Страница 17: ...12 Procedure for repairing the set 17 SA VK61DEE ...
Страница 58: ...17 3 1 Cassette Deck Section 17 3 2 Adjustment Point 17 3 Alignment Points 58 SA VK61DEE ...
Страница 132: ...24 1 Deck Mechanism RAA3412 S 24 1 1 Deck Mechanism Parts Location 132 SA VK61DEE ...
Страница 133: ...133 SA VK61DEE ...
Страница 135: ...24 2 CD Loading Mechanism RD DAC036 S 24 2 1 CD Loading Mechanism Parts Location 135 SA VK61DEE ...
Страница 136: ...136 SA VK61DEE ...
Страница 137: ...137 SA VK61DEE ...
Страница 139: ...24 3 Cabinet 24 3 1 Cabinet Parts Location 139 SA VK61DEE ...
Страница 140: ...140 SA VK61DEE ...
Страница 141: ...141 SA VK61DEE ...
Страница 156: ...24 6 Packaging 156 SA VK61DEE PRT0406 D K J N L ...