8.6.3. Power Supply & Digital Amplifier Error Code Table
Error
Code
F61
The abnormalities
In normal operation, when DCDET2 goes
Press [ STOP] on main
in an output or power
to "L" (Low) (Not during POWER OFF
unit for next error.
supply circuit of
condition), F61 appears on FLDisplay
POWER AMP
for 1 second and PCONT goes to
"L" (Low).This is due to speaker output
has DC voltage or fan is not working.
F76
Abnormality in the
In normal operation when DCDET1 is
Press [ STOP] on main
output voltage of
detected "L" (Low) for two consecutive
unit for next error.
stabilized power
times, F76 is displayed on FL for
supply
1 second and after that PCONT will be
turned to "L" (Low). This is due to any of
the DC voltages (+9V, +7V, -7V, +5V,
+5.3V etc.) C22 not available.
Diagnosis Contents