Panasonic S-60PE3R Скачать руководство пользователя страница 1

C8041-

Panasonic Corporation

1006 Kadoma, Kadoma City, Osaka, Japan

INDOOR UNIT

S-160PE3R

Ducted Type 

S-60PE3R 

S-71PE3R 

S-100PE3R 

S-125PE3R 

S-140PE3R

Ducted (E3 type)

OUTDOOR UNIT

Single Split

(Single-phase) 

Single Split

(3-phase) 

PZ2 Type

U-100PZ2R8

U-125PZ2R8

U-140PZ2R8

PZ2 Type

U-60PZ2R5

U-71PZ2R5

U-100PZ2R5

U-125PZ2R5

U-140PZ2R5

PZH2 Type

U-100PZH2R8

U-125PZH2R8

U-140PZH2R8

U-160PZH2R8

PZH2 Type

U-71PZH2R5

U-100PZH2R5

U-125PZH2R5

U-140PZH2R5

U-160PZH2R5

PZH3 Type

U-100PZH3R8

U-125PZH3R8

U-140PZH3R8

U-160PZH3R8

PZH3 Type

U-71PZH3R5

U-100PZH3R5

U-125PZH3R5

U-140PZH3R5

U-160PZH3R5

PZ3 Type

U-100PZ3R8

U-125PZ3R8

U-140PZ3R8

PZ3 Type

U-60PZ3R5

U-71PZ3R5

U-100PZ3R5

U-125PZ3R5

U-140PZ3R5

Содержание S-60PE3R

Страница 1: ... U 125PZ2R8 U 140PZ2R8 PZ2 Type U 60PZ2R5 U 71PZ2R5 U 100PZ2R5 U 125PZ2R5 U 140PZ2R5 PZH2 Type U 100PZH2R8 U 125PZH2R8 U 140PZH2R8 U 160PZH2R8 PZH2 Type U 71PZH2R5 U 100PZH2R5 U 125PZH2R5 U 140PZH2R5 U 160PZH2R5 PZH3 Type U 100PZH3R8 U 125PZH3R8 U 140PZH3R8 U 160PZH3R8 PZH3 Type U 71PZH3R5 U 100PZH3R5 U 125PZH3R5 U 140PZH3R5 U 160PZH3R5 PZ3 Type U 100PZ3R8 U 125PZ3R8 U 140PZ3R8 PZ3 Type U 60PZ3R5 ...

Страница 2: ...rvice personnel or the appliance WARNING This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death CAUTION This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage Prohibited matters Matters to be observed Read these Operating Instructions carefully before using this air conditioner If you still ...

Страница 3: ...ord joint cord extension cord or unspecified cord to prevent overheating and fire WARNING The appliance shall be stored in a room without continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater Be aware that refrigerants may not contain an odour An unventilated area where the appliance using flammable refrigerants is installed shal...

Страница 4: ...ence and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Keep the fire alarm and the air outlet at least 1 5m away from the unit Do not cool or heat the room too much if babies or invalids are present Do not turn the air conditio...

Страница 5: ...r continuous use ON Tips for Energy Saving Avoid Do not block the air intake and outlet of the unit If either is obstructed the unit will not function well causing malfunction During cooling operation use sunshades blinds or curtains to prevent direct sunlight from entering the room Do Always keep the air filter clean A clogged filter will impair the performance of the unit Maintenance P 7 To prev...

Страница 6: ... CZ RWRC3 For all indoor units Infrared Remote Controller Model No CZ RTC5B For all indoor units Model No CZ RTC6 For all indoor units Type F3 Middle Static Pressure Duct Air outlet duct Suspension bolt Ceiling material Air outlet grille Field supplied At standard installation Horizontal installation in the ceiling rear side air intake 01_320325_Eng indb 6 2020 01 24 14 35 49 Label attached to the...

Страница 7: ...o heat pump system In that case use another heating appliance Defrosting This appliance may start defrosting operation to melt frost formed in the outdoor unit 1 Defrosting starts The indoor unit fan stops or the speed becomes extremely slow STANDBY appears 2 Heating operation resumes after several minutes The indoor unit fan remains stopped or it will run at a very slow speed until the indoor hea...

Страница 8: ...using the air in the room to give a healthy air It also reduces the smell in the room and constrains propagations of mold and bacteria When purchased the nanoe X function is designed to automatically operate If you wish to set to OFF refer to the operating instructions for the remote controller adaptable to nanoe X function The effect of nanoe X may decrease slightly depending on the installation ...

Страница 9: ...tion is in process The fan is rotating for a while even though operation stops The fan may rotate to dry the heat exchanger depending on the setting Dust is discharged Dust accumulated inside the indoor unit is discharged At the initial high speed operation the fan sometimes rotates faster than the setting speed 3 to 30 minutes motor rotation is within the range of use Humming noise comes out This...

Страница 10: ...ooling mode Doors or windows are open The air filter is clogged See Maintenance P 7 Too many heat sources in the room in cooling mode Use minimum heat sources and in a short time Too many people in the room in cooling mode Lower the temperature setting or change to High or Strong If your air conditioner does not work properly even after checking each item of Before Requesting Services and Troubles...

Страница 11: ...10 Memo PTW18_C8041 2911_OI indd 10 PTW18_C8041 2911_OI indd 10 1 17 2019 9 47 47 AM 1 17 2019 9 47 47 AM ...

Страница 12: ...11 Memo PTW18_C8041 2911_OI indd 11 PTW18_C8041 2911_OI indd 11 1 17 2019 9 47 47 AM 1 17 2019 9 47 47 AM ...

Страница 13: ...12 Panasonic Corporation Website http panasonic net Panasonic Corporation 2020 Printed in China PTW18_C8041 2911_OI indd 12 PTW18_C8041 2911_OI indd 12 1 17 2019 9 47 47 AM 1 17 2019 9 47 47 AM ...