Asynchronous
(image output first):
An inspection is complete before outputting images, and then PV500 outputs
images when it can. When the interval of START signal input (the period between
inspection start and the next inspection start) is short, and Image Output is not
completed after several inspections, PV500 completes Image Output by delaying
the next inspection start.
Asynchronous
(inspection first):
An inspection is complete before outputting images, and then PV500 outputs
images when it can. When the interval of START signal input (the period between
inspection start and the next inspection start) is short, and image output is not
completed, PV500 internally stores images up to a certain number as images to be
output. If the number of images exceeds the storable capacity, new images cannot be
stored in PV500 until enough space for storing is created by outputting the image that
have been stored in PV sequentially. Inspections are executed on images that cannot
be stored, however, image output is not executed.
1
. Select “System Settings” >
"Operation".
The setting window of operation is
displayed.
2.
Specify “Output Results”.
Default: Synchronous
3.
Specify “Image Output”.
Default: Synchronous
Parallel I/O Reset Condition
This item is to select reset timing of OUT signal when outputting inspection result through Parallel I/O connector
and Parallel I/O terminal.
Hold (default):
To hold until outputting the next result.
When the first and second inspections turn on OUT0 signal, the signal keeps ON until the third
output of inspection result without turning off.
Reset:
All OUT signals turn off when TACT signal turns off.
Refer to Chapter 8.3 “Timing Chart” (page 378) for details.
Inspecting with Internal Trigger
(Continuous Inspection)
This method executes inspections repeatedly before receiving START signal from the external device. This is
"Continuous Inspection” and helpful to inspect continuously due to a long object. A signal input from the
external device can stop repeating inspections.
1.
Select “System Settings” > "Operation".
The setting window of operation is displayed.
2.
Select whether you inspect repeatedly in “Continuous Inspection”.
No (Once) (default):
Executes an inspection by START signal input.
Automatic: After Trigger:
After PV500 starts up, inputting START signal at the start of the first
inspection executes inspections repeatedly.
Automatic: After Power On:
After PV500 starts up, inspection is repeatedly executed soon. START
signal input is not necessary.
Содержание PV-500
Страница 1: ......
Страница 10: ......
Страница 11: ...9 Names and Descriptions Chapter 1 INDEX Chapter 1 Names and Descriptions ...
Страница 21: ...19 Installation and Wiring Chapter 2 INDEX Chapter 2 Installation and Wiring ...
Страница 37: ...35 Basic Operation Chapter 3 INDEX Chapter 3 Basic Operation ...
Страница 55: ...53 Setting Inspection Conditions Chapter 4 INDEX Chapter 4 Setting Inspection Conditions ...
Страница 315: ...313 Setting of Operation and RUN Menu Chapter 5 INDEX Chapter 5 Setting of Operation and RUN Menu ...
Страница 331: ...329 Environment Settings Chapter 6 INDEX Chapter 6 Environment Settings Changing System Settings ...
Страница 345: ...343 Chapter 7 Changing Configuration INDEX Chapter 7 Changing Configuration TOOL ...
Страница 375: ...373 Operation and Data Output through I O Terminals Chapter 8 INDEX ...
Страница 390: ......
Страница 391: ...389 Control with Communication Port Chapter 9 INDEX Chapter 9 Control with Communication Port ...
Страница 430: ......
Страница 431: ...429 PVWIN Chapter 10 INDEX Chapter 10 PVWIN ...
Страница 437: ...435 Chapter 11 Specifications and List of Product Numbers INDEX Chapter 11 Specifications and List of Product Numbers ...
Страница 493: ......
Страница 494: ......