272
Se
tt
ing I
n
s
p
e
c
tio
n C
on
d
it
ions
C
h
ap
te
r 4
6.
Set “Output Signal Guarantee Time”.
Settable range is 1 - 1000 ms. (Default: 10 ms)
When Handshaking is not employed:
OUT signal is output in the doubled cycle of the time specified in this item.
When Handshaking is employed:
After handshaking of the first inspection, output of the second inspection is not executed during
"Output Signal Guarantee Time".
7.
Set "Timeout (ms)" when you employ handshake.
Settable range is 4 - 2000 ms. (Default: 5000 ms)
Specify maximum time from data output to ACKNOWLEDGE signal (data receipt completion signal) input
from the external device. If ACKNOWLEDGE signal is not input within this period, a time error occurs and
ERROR0 signal is output.
Output Example when outputting only Judgement
Output Data Assignment in the case of “8 bit” (1000-data output)
OUT7
OUT6
OUT5
OUT4
OUT3
OUT2
OUT1
OUT0
1st
JDC007
JDC006
JDC005
JDC004
JDC003
JDC002
JDC001
JDC000
2nd
JDC015
JDC014
JDC013
JDC012
JDC011
JDC010
JDC009
JDC008
:
125th
JDC999
JDC998
JDC997
JDC996
JDC995
JDC994
JDC993
JDC992
Output Data Assignment in the case of “16 bit” (1000-data output)
OUT
15
OUT
14
OUT
13
OUT
12
OUT
11
OUT
10
OUT
9
OUT
8
OUT
7
OUT
6
OUT
5
OUT
4
OUT
3
OUT
2
OUT
1
OUT
0
1st
JDC
015
JDC
014
JDC
013
JDC
012
JDC
011
JDC
010
JDC
009
JDC
008
JDC
007
JDC
006
JDC
005
JDC
004
JDC
003
JDC
002
JDC
001
JDC
000
2nd
JDC
031
JDC
030
JDC
029
JDC
028
JDC
027
JDC
026
JDC
025
JDC
024
JDC
023
JDC
022
JDC
021
JDC
020
JDC
019
JDC
018
JDC
017
JDC
016
:
63rd
OFF OFF OFF OFF OFF OFF OFF OFF
JDC
999
JDC
998
JDC
997
JDC
996
JDC
995
JDC
994
JDC
993
JDC
992
Until the last number of data which has been set a judgement expression, data will be output. For example,
when No.0-5 and No.30 are set, No.0-30 are output and after No.30 is not output. No.6-29 are output “OFF”.
In the case of Execution Mode = Automatic Switch
(When the lastly executed block = Block No.3, Bit Width [8 bit])
OUT7
OUT6
OUT5
OUT4
OUT3
OUT2
OUT1
OUT0
1st: Judgement result of Block No.3
JDC
307
JDC
306
JDC
305
JDC
304
JDC
303
JDC
302
JDC
301
JDC
300
:
Afterwards, outputs to the last number of judgement expression created
in Block No.3.
*Only the results of the block executed lastly are output.
Содержание PV-500
Страница 1: ......
Страница 10: ......
Страница 11: ...9 Names and Descriptions Chapter 1 INDEX Chapter 1 Names and Descriptions ...
Страница 21: ...19 Installation and Wiring Chapter 2 INDEX Chapter 2 Installation and Wiring ...
Страница 37: ...35 Basic Operation Chapter 3 INDEX Chapter 3 Basic Operation ...
Страница 55: ...53 Setting Inspection Conditions Chapter 4 INDEX Chapter 4 Setting Inspection Conditions ...
Страница 315: ...313 Setting of Operation and RUN Menu Chapter 5 INDEX Chapter 5 Setting of Operation and RUN Menu ...
Страница 331: ...329 Environment Settings Chapter 6 INDEX Chapter 6 Environment Settings Changing System Settings ...
Страница 345: ...343 Chapter 7 Changing Configuration INDEX Chapter 7 Changing Configuration TOOL ...
Страница 375: ...373 Operation and Data Output through I O Terminals Chapter 8 INDEX ...
Страница 390: ......
Страница 391: ...389 Control with Communication Port Chapter 9 INDEX Chapter 9 Control with Communication Port ...
Страница 430: ......
Страница 431: ...429 PVWIN Chapter 10 INDEX Chapter 10 PVWIN ...
Страница 437: ...435 Chapter 11 Specifications and List of Product Numbers INDEX Chapter 11 Specifications and List of Product Numbers ...
Страница 493: ......
Страница 494: ......