Lamp replacement procedure
1
Turn power off, wait until power
indicator stops blinking red, then
unplug the power cord from the
wall outlet and confirm that the area
around the lamp unit has cooled
down.
POWER
button /
POWER
indicator
Lamp Re placement
3
Loosen the Lamp cover screw.
First read caution and warn ing
labels on lamp cover. Then, loosen
the lamp cover screw by using a
screwdriver.
Lamp unit screw
Screwdriver
4
Loosen the lamp unit screw with a
screwdriver. Then, grasp the lamp
unit as shown in the diagram, and
slowly remove from the projection
display.
2
Remove the Front cover.
Place your
fingertips under the Front cover and
pull it from the projection display.
Lamp unit handle
Lamp cover handle
6
Replace the Lamp unit and cover
screws.
Tighten the lamp unit/cover
screw with a screwdriver.
• Properly dispose of old lamp. Please see the
operating instructions for the projection display.
Note
7
Replace the Front cover.
5
Insert the new lamp unit being careful
of the insertion direction.
• Press on the arrow mark making sure
insertion is done correctly.
Lamp time reset procedure
1
Be sure the power cord is plugged
into a properly grounded wall outlet.
Then, press the POWER button on the
projection display or the remote control
to turn the unit on.
Warning:
Perform lamp time reset only when the lamp has
been replaced.
When lamp time reset is finished, the LAMP
indicator goes out.
Note
After lamp re placement,
follow the pro cedure below
3
When reset
procedure
is complete,
the screen on
the right will
appear.
and
Lamp cover screw
LAMP indicator
2
While pressing the VOL- button on
the projection display, hold down the
PIP or SPLIT button on the remote
control at same time for more than
5 seconds.
LSQC0334 C
LAMP TIME WAS
RESET TO 0.
END
Front cover
This product has a High Intensity Discharge (HID)
lamp that contains a small amount of mercury.
Disposal of these materials may be regulated
in your community due to environmental
considerations.
For disposal or recycling information please contact
your local authorities, or the Electronics Industries
Alliance: <http://www.eiae.org.>
CAUTION:
Because of the possibility of injury, strictly follow
the replacement procedure below.
• Please wait more than one hour for lamp
replacement.
[If you need to replace the lamp more urgently]
• The Projection display has a forced cooling
feature. After the POWER button is turned OFF,
and during the first minute of the normal cooling
fan operation, press the VOL+ button on the
projection display and button on the remote
control at same time for more than 5 seconds. The
cooling fan operates for about 10 minutes. The
LAMP indicator flashes red 5 times every 5
seconds.
Attach the lamp unit and lamp unit housing door
securely. If the lamp unit and lamp unit housing
door are not attached securely, the protective
circuit will be activated and the lamp will not turn
on.
* This screen may be
different from the actual
screen.
For models PT-50LC13/
PT-60LC13/PT-50LCX63/
PT-60LCX63/PT-43LCX64/
PT-50LCX64/PT-60LCX64
For models PT-43LC14/
PT-50LC14/PT-60LC14
CAUTION
• Because the lamp unit is hot immediately after
its use, touching it may cause burns.
Please allow the lamp to cool before handling or
replacing the lamp unit.
•