background image

 Lamp replacement procedure

1

 Turn power off, wait until power 

indicator stops blinking red, then 

unplug the power cord from the 

wall outlet and confirm that the area 

around the lamp unit has cooled 

down.

POWER

button /

POWER

indicator

Lamp Re placement

3

 Loosen the Lamp cover screw.

First read caution and warn ing

labels on lamp cover. Then, loosen 

the lamp cover screw by using a 

screwdriver.

Lamp unit screw

Screwdriver

4

Loosen the lamp unit screw with a 

screwdriver. Then, grasp the lamp 

unit as shown in the diagram, and 

slowly remove from the projection 

display.

2

 Remove the Front cover. 

Place your 

fingertips under the Front cover and 

pull it from the projection display.

Lamp unit handle

Lamp cover handle

6

 Replace the Lamp unit and cover 

screws.

Tighten the lamp unit/cover 

screw with a screwdriver.

• Properly dispose of old lamp. Please see the

operating instructions for the projection display.

Note

7

 Replace the Front cover.

5

Insert the new lamp unit being careful 

of the insertion direction.

• Press on the arrow mark making sure 

insertion is done correctly.

 Lamp time reset procedure

1

Be sure the power cord is plugged 

into a properly grounded wall outlet. 

Then, press the POWER button on the 

projection display or the remote control 

to turn the unit on.

Warning:

Perform lamp time reset only when the lamp has 

been replaced.

When lamp time reset is finished, the LAMP 

indicator goes out.

Note

After lamp re placement,

follow the pro cedure below

3

When reset 

procedure

is complete, 

the screen on 

the right will 

appear.

and

Lamp cover screw

LAMP indicator

2

While pressing the VOL- button on 

the projection display, hold down the 

PIP or SPLIT button on the remote 

control at same time for more than 

5 seconds.

LSQC0334 C

      LAMP TIME WAS
       RESET TO 0.

                END

Front cover

This product has a High Intensity Discharge (HID) 

lamp that contains a small amount of mercury.

Disposal of these materials may be regulated 

in your community due to environmental 

considerations.

For disposal or recycling information please contact 

your local authorities, or the Electronics Industries 

Alliance: <http://www.eiae.org.>

CAUTION:

Because of the possibility of injury, strictly follow 

the replacement procedure below.

• Please wait more than one hour for lamp 

replacement.

  [If you need to replace the lamp more urgently]

• The Projection display has a forced cooling 

feature. After the POWER button is turned OFF, 

and during the first minute of the normal cooling 

fan operation, press the VOL+ button on the 

projection display and   button on the remote 

control at same time for more than 5 seconds. The 

cooling fan operates for about 10 minutes. The 

LAMP indicator flashes red 5 times every 5 

seconds.

Attach the lamp unit and lamp unit housing door 

securely. If the lamp unit and lamp unit housing 

door are not attached securely, the protective 

circuit will be activated and the lamp will not turn 

on.

* This screen may be 

different from the actual 

screen.

For models PT-50LC13/

PT-60LC13/PT-50LCX63/

PT-60LCX63/PT-43LCX64/

PT-50LCX64/PT-60LCX64

For models PT-43LC14/

PT-50LC14/PT-60LC14

CAUTION

• Because the lamp unit is hot immediately after

its use, touching it may cause burns.

Please allow the lamp to cool before handling or

replacing the lamp unit. 

Отзывы: