Initial setting (operation setting)
Set the items for the operating method depending on the projector’s application and duration of usage.
After completed the initial setting, you can change the settings of each item from the [PROJECTOR SETUP]
menu
→
[OPERATION SETTING]. If you change the settings while using the projector, the duration until the
luminance of the light source decreases by half may shorten or the luminance may decrease.
This initial setting (operation setting) is prepared to complete the settings at once during the installation when
the operation of the projector is predetermined. When the [PROJECTOR SETUP] menu
→
[INITIALIZE]
→
[ALL USER DATA] is executed, do not change the setting in the initial setting (operation setting), but press the
<ENTER> button and proceed to next initial setting (installation setting). If you need to change the setting, ask the
person responsible for this projector (such as a person in charge of equipment or operation).
2/7
83.3%
83.3%
INITIAL SETTING
SET
CHANGE
MENU SELECT
OPERATING MODE
NORMAL
ENTER
LIGHT OUTPUT
MAX LIGHT OUTPUT LEVEL
Set the way to use the projector. For details, please
refer to the operating instructions "When the initial
setting screen is displayed".
Note
f
The preceding initial setting screen is displayed when the projector is switched on for the first time after purchase. If the [PROJECTOR
SETUP] menu
→
[INITIALIZE]
→
[ALL USER DATA] is executed, the settings before execution are displayed in [OPERATING MODE] and
[MAX LIGHT OUTPUT LEVEL].
f
f
For details on each setting item, refer to the [PROJECTOR SETUP] menu
→
[OPERATION SETTING].
1) Press
as
to select [OPERATING MODE].
2) Press
qw
to switch the item.
f
The items will switch each time you press the button.
f
Set [OPERATING MODE] to anything other than [LONG LIFE1], [LONG LIFE2], or [LONG LIFE3] when
using the projector at an altitude of 2 700 m (8 858') or higher above sea level.
f
Set [OPERATING MODE] to anything other than [LONG LIFE1], [LONG LIFE2], or [LONG LIFE3] when
using the optional Smoke Cut Filter (Model No.: ET-SFR330).
[HIGH]
*1
The life of the light source will shorten compared to [NORMAL], but set this item when a higher
luminance than [NORMAL] is required. The estimated runtime is approximately 8 000 hours.
[NORMAL]
*1
Set this item when high luminance is required. The estimated runtime is approximately 20 000 hours.
(Factory default setting)
[LONG LIFE1]
*1
The luminance will decrease compared to [NORMAL], but set this item to increase the expected life of
the light source. The estimated runtime is approximately 43 000 hours.
[LONG LIFE2]
*1
The luminance will decrease compared to [LONG LIFE1], but set this item to increase the expected
life of the light source. The estimated runtime is approximately 61 000 hours.
[LONG LIFE3]
*1
The luminance will decrease compared to [LONG LIFE2], but set this item to increase the expected
life of the light source. The estimated runtime is approximately 87 000 hours.
[USER1]
Set [MAX LIGHT OUTPUT LEVEL] and [LIGHT OUTPUT] individually.
[USER2]
[USER3]
*1
The runtime is an estimation when the [PICTURE] menu
→
[DYNAMIC CONTRAST] is set to [3].
f
when [NORMAL], [LONG LIFE1], [LONG LIFE2], or [LONG LIFE3] is selected.
3) Press
as
to select [MAX LIGHT OUTPUT LEVEL].
4) Press
qw
to adjust.
Operation
Adjustment
Range of adjustment
Press
w
.
Increases the maximum level of brightness correction.
8.0 % - 100.0 %
Press
q
.
Decreases the maximum level of brightness correction.