[NETWORK] menu
ENGLISH - 93
Settings
▶
■
[E-mail set up] page
E-mail address set in advance for use when there is a problem or when the usage time of a lamp reaches a
set value.
E-mail can be sent to (maximum two locations).
Click [Detailed set up] → [E-mail set up].
(1)
(2)
(3)
(4)
(5)
(6)
(1) [ENABLE]
Select [Enable] to use the E-mail function.
(2) [SMTP SERVER NAME]
Enter the IP address or the server name of the
E-mail server (SMTP). To enter the server name, the
setup of the DNS server is required.
(3) [MAIL FROM]
Enter the E-mail address of the projector. (Up to 63
characters in single byte)
(4) [MEMO]
You can enter information such as the location of
the projector that notifies the sender of the E-mail.
(Up to 63 characters in single byte)
(5) [MINIMUM TIME]
Change the minimum interval for the temperature
warning mail. The default value is 60 minutes. In this
case, another E-mail will not be sent for 60 minutes
after sending the temperature warning mail even if it
reaches the warning temperature.
(6) [INTAKE AIR TEMPERATURE]
Change the temperature setting for the temperature
warning mail. A temperature warning mail is sent
when the temperature exceeds this value.
(8)
(7)
(7) [E-MAIL ADDRESS 1]
Enter the E-mail address to be sent.
(8) Settings of the conditions to send E-mail
Select the conditions to send E-mail.
[MAIL CONTENTS]:
Select either [NORMAL] or [SIMPLE].
[ERROR]:
An E-mail message is sent when an error
occurred in the self-diagnosis.
[LAMP1 RUNTIME]:
An E-mail message is sent when the remaining
lamp on time for the lamp 1 has reached the
value set at the right field.
[LAMP2 RUNTIME]:
An E-mail message is sent when the remaining
lamp on time for the lamp 2 has reached the
value set at the right field.
[INTAKE AIR TEMPERATURE]:
An E-mail message is sent when the air intake
temperature has reached the value set at the
above field.
[PERIODIC REPORT]:
Place a check mark on this when E-mail is to be
sent periodically.
It will be sent on the days and time with the
check mark.