PICTURE menu
E
NGLISH - 21
COLOUR TEMPERATURE
You can adjust the white balance of the projected image.
Less
bluish
More
bluish
Setting range: −6 to +6
DYNAMIC IRIS
You can switch automatic adjustment of the lamp and
the lens iris on/off.
ON:
Automatic adjustment
OFF:
No adjustment
WAVEFORM MONITOR
You can monitor whether or not the luminance level
of the input signal is in the recommended range by
displaying it in the waveform monitor. If the waveform
is not in the recommended range, adjust it for the
best quality. See “Adjusting the signal condition with a
waveform” on page 14.
OFF
FULL SCAN(Y)
FULL SCAN(R)
FULL SCAN(G)
FULL SCAN(B)
SINGLE LINE SCAN(Y)
SINGLE LINE SCAN(R)
SINGLE LINE SCAN(G)
SINGLE LINE SCAN(B)
MONITOR POSITION
UPPER LEFT
AUTO ADJUST
Press ▲ ▼ to move to the required waveform
1.
style.
Press the
2.
ENTER
button to select.
The
WAVEFORM MONITOR
will be displayed.
NOTE:
When the
•
WAVEFORM MONITOR
is set to
OFF
, the
AUTO ADJUST
is not displayed.
The waveform of the
•
WAVEFORM MONITOR
will
not be displayed correctly with a noisy equipment or
source.
The
•
WAVEFORM MONITOR
adjusts the signal level
based on the reference signal which consists of 0 %
and 100 %. The over scanned reference signal which
runs off the edge of the screen, below 0 % or over
100 % signal level will not be adjusted correctly.
MONITOR POSITION
J
When the
FULL SCAN
is selected, press ▲ ▼ ◄
► to adjust the position of the monitor.
See “Adjusting the signal condition with a waveform”
on page 14.
AUTO ADJUST
J
You can switch on/off the automatic adjustment
system in each item.
BLACK LEVEL ADJUST
Adjust the black level of luminance (Y) to 0 %.
ON
WHITE LEVEL ADJUST
Adjust the white level of luminance (Y) to
100 %.
ON
RGB ADJUST (BLACK)
Adjust the black level of colours (R/G/B) to 0 %.
OFF
RGB ADJUST (WHITE)
Adjust the white level of colours (R/G/B) to
100 %.
OFF
Press ▲ ▼ and select the required item.
1.
Press ◄ ► and switch on/off.
2.
Press ▲ ▼ and select
3.
START AUTO ADJUST
and press the
ENTER
button.
The confirmation screen will be displayed.
Press ◄ ► and select
4.
OK
.
Press the
5.
ENTER
button.
Adjustment example
J
Project a commercial test signal for picture
adjustment on the screen and press the
WAVEFORM MONITOR
button.
100%
50%
0%
100%
50%
0%
100%
50%
0%
ENTER
ENTER
Adjust to 100
%
Adjust to 100 %
Monitor position
Monitor position
Signal level
Signal level
Adjust to 0 %
Adjust to 0 %
Image
displayable area
Image
displayable area
With
COMPUTER
(except HD) or
HDMI
(Expand)