Instructions for the Electrical Installer

(PAW-PACR3)

For your safety

Read the following instructions carefully, and carry out secure installation and electrical work.

The precautions given in this manual consist of specific “Warnings” and “Cautions”. They provide important safety-related information. Be sure to 

strictly observe all safety procedures. The labels and their meanings are as described below.

This symbol refers to a hazard or unsafe procedure or practice that can result in personal injury or product or 
property damage.

This symbol refers to a hazard or unsafe procedure or practice that can result in severe personal injury or death.

* After installation is completed, perform a test run to check for operating trouble. Explain operating procedures to the customer following the

central control device Operation Manual and then request the customer to store this Instructions for the Electrical Installer together with the
central control device Operation Manual.

1

Material

The package includes following items:

• Controller box (Fig. 1-1)

• External power supply for DC 24V (Fig. 1-2)

• 2 pieces cable bushings M20 (Fig. 1-2)

• 3 pieces PAW-T10* (PCB + wire) (Fig. 1-3)

* It is necessary 1 piece for each indoor unit or group of      

indoor units.

Required Installation material (field supplied):

• Control wire min. 5 x 0,5 mm² (similar IEC 60227-5)

• Single wire LiY type 1 x 0,5 mm²

• 4 screws diameter 5 mm and wall plugs 

• Set of standard electric installation tools

Fig. 1-1

Fig. 1-2

Fig. 1-3

Содержание PAW-PACR3

Страница 1: ... injury or death After installation is completed perform a test run to check for operating trouble Explain operating procedures to the customer following the central control device Operation Manual and then request the customer to store this Instructions for the Electrical Installer together with the central control device Operation Manual 1 Material The package includes following items Controller...

Страница 2: ... the unit may come into contact with water or in any extremely humid locations Avoid installing in any location that is subject to excessive vibration or physical impacts 1 Install PAW T10 to each individual controlled indoor unit or to one single unit of each group master or slave by inserting the PCB holder into the appropriate holes 2 Connect the supplied T10 wire to the T10 connector of the in...

Страница 3: ...3 Wall mounted K1 type ...

Страница 4: ...4 ...

Страница 5: ...5 ...

Страница 6: ...not extend this wire by standard wires as it is a thermocoupler element you need special extension cable for thermocouple elements type K The temperature sensor is flexible and may be ajusted according to local needs however do not use force in order to not brake it Maximum wire length between the control box and each of the indoor units must not exceed 10 m Within 1 5 m of the control box a 100 2...

Страница 7: ...e corners of the front cover and carefully lift the cover up then you may turn it beside Be careful do not use force and do not let it hang down just by the internal wiring Fig 3 1 Fig 3 1 4 Prepare the holes in the wall according to the illustration here Fig 2 1 Please use the holes red marked in the drawing under the screws of the cover ...

Страница 8: ... 2 to PAW T10 contact 1 Start Stop Unit 2 to PAW T10 contact 2 Start Stop Unit 1 to PAW T10 contact 1 Start Stop Unit 1 to PAW T10 contact 2 COM contact of Status Unit 3 to PAW T10 contact 7 COM contact of Status Unit 2 to PAW T10 contact 7 COM contact of Status Unit 1 to PAW T10 contact 7 Alarm signal Unit 3 to PAW T10 contact 9 Operation signal Unit 3 to PAW T10 contact 6 Alarm signal Unit 2 to ...

Страница 9: ...use the supplied M20 cable bushings Even insertion by the backside is possible however it may be difficult to run the wires then through the box under the internal mounting plate The communication wires shouldn t exceed 10 m In case you need a longer distance please choose a bigger wiring diameter Do not run the communication lines through the same conduit as any local power supply cable or run cl...

Страница 10: ...n performed and good operation verified on each system Each system is equipped with a remote controller it can be any local or centralized controller which is suitable for that model 1 Please cut the jumper JP001 on each indoor unit main PCB See Fig 4 1 This will convert T10 signals to static ones Fig 4 1 2 Set the 2 or 3 indoor units or groups to the desired mode and temperature Take care that it...

Страница 11: ...data Pressing a switch of the digit for which you would like to change the numerical value during the data change adds one to the numerical value displayed Data display blinks during the data change 5 is used to start stop operation No special meaning in this case Lock display Shows that the switches are locked RUN PROG Display Displays the operation mode RUN or PROG ERR ALARM display Indicates wh...

Страница 12: ...ed at that time because maybe power supply missing on indoor or outdoor unit s the program will not run properly In this case you can simply switch the controller off on again to repeat the automatic detection Normal status is indicated by a green screen Fig 4 2 Initial screen Actual detected room temperature is shown 3 Pressing the MODE button shortly less than 2 seconds toggles between the 8 ava...

Страница 13: ...temperature above which the 3rd unit and or the external alarm should be activated between 20 40 C cool and 18 45 C heat in 0 1 K steps Press 0 for the digits after the comma press 1 for the ones and 2 for the tenths If you exceed the limit by default the next highest or lowest limit is chosen after confirmation Finish the temperature limit 2 setting by pressing shortly the 1 2 SET button 7 Press ...

Страница 14: ...ion is in progress You may stop the redundancy operation at any time by simply pressing button 5 in this screen again The symbol will go off then 8 Press again the MODE button shortly less than 2 seconds to get to the alarm temperature activation screen Upper line indicating Alarm lower line indicating on or off Here you can set if an alarm should be output when a temperature limit has been exceed...

Страница 15: ...m signal is output During an alarm you can still go to the other screens In the main screen however the alarm will be displayed as long as there is an alarm present Fig 4 7 Following will cause an alarm Set temperature limit is exceeded in case Alarm is set to on Any of the units outputs an alarm In case any of the set temperature limits is exceeded this alarm can be rest by simply pressing the 1 ...

Страница 16: ...an alarm will be output in case this option has been activated If the second temperature threshold limit is either exceeded during cool mode or undershoot during heat mode a second unit will be started and optional an alarm will be output If the third temperature threshold limit is either exceeded during cool mode or undershoot during heat mode a third unit will be started and optional an alarm wi...

Страница 17: ...ce 10 to 55 Hz 1 cycle min Double amplitude 0 75 mm 10 min on X Y and Z axes Shock resistance 98 m s 4 times on X Y and Z axes Noise resistance 1000V p p with pulse widhts 50 ns 1 s based on in house measurements Operating condition Free from corrosive gases and excessive dust Protection IP66 compliant Only when cabling is inserted properly Weight Approx 1160 g without packing material 8 Outer Dim...

Отзывы: