– 129 –
Chapter 7 Menu Operations — Menu list
Item
Description of settings
Remark
BATTERY SELECT
Sets the battery type.
[HYTRON50], [HYTRON140], [DIONIC HC], [DIONIC90], [DIONIC160],
[ENDURA7], [ENDURA10], [PAG L96e], [TYPE A], [TYPE B], [BAT STAT]
f
When using a battery whose charge level is
detected using a percentage, near end and
end operation is conducted according to the
percentage of the charge level if [BAT STAT] is
selected.
f
Set a near end percentage for [BAT STAT NEAR],
or an end percentage for [BAT STAT END]
depending on the battery used.
f
When the battery charge level percentage cannot
be detected, it will follow the setting value of
[TYPE A] even if it is set to [BAT STAT]. Make
sure that the setting values [TYPE A FULL] (fully
charged), [TYPE A NEAR] (near end), or [TYPE
A END] (end) is appropriate for the battery being
used.
BATTERY MODE
Sets the near end.
[AUTO]
Near end is set automatically with the battery selected with
[BATTERY SELECT].
[MANUAL]
Sets the near end voltage manually.
HYTRON50 NEAR
Sets the near end voltage of [HYTRON50]. (Can be adjusted in 0.1 V units.)
[11.0V] ... [13.4V] ... [15.0V]
HYTRON140 NEAR
Sets the near end voltage of [HYTRON140]. (Can be adjusted in 0.1 V units.)
[11.0V] ... [13.1V] ... [15.0V]
DIONIC HC NEAR
Sets the near end voltage of [DIONIC HC]. (Can be adjusted in 0.1 V units.)
[11.0V] ... [13.1V] ... [15.0V]
DIONIC90 NEAR
Sets the near end voltage of [DIONIC90]. (Can be adjusted in 0.1 V units.)
[11.0V] ... [13.5V] ... [15.0V]
DIONIC160 NEAR
Sets the near end voltage of [DIONIC160]. (Can be adjusted in 0.1 V units.)
[11.0V] ... [13.4V] ... [15.0V]
ENDURA7 NEAR
Sets the near end voltage of [ENDURA7]. (Can be adjusted in 0.1 V units.)
[11.0V] ... [13.4V] ... [15.0V]
ENDURA10 NEAR
Sets the near end voltage of [ENDURA10]. (Can be adjusted in 0.1 V units.)
[11.0V] ... [13.4V] ... [15.0V]
PAG L96e NEAR
Sets the near end voltage of [PAG L96e]. (Can be adjusted in 0.1 V units.)
[11.0V] ... [13.1V] ... [15.0V]
TYPE A FULL
Sets the full voltage of [TYPE A]. (Can be adjusted in 0.1 V units.)
[12.0V] ... [15.5V] ... [17.0V]
TYPE A NEAR
Sets the near end voltage of [TYPE A]. (Can be adjusted in 0.1 V units.)
[11.0V] ... [13.0V] ... [15.0V]
TYPE A END
Sets the end voltage of [TYPE A]. (Can be adjusted in 0.1 V units.)
[11.0V] ... [12.7V] ... [15.0V]
TYPE B FULL
Sets the full voltage of [TYPE B]. (Can be adjusted in 0.1 V units.)
[12.0V] ... [15.6V] ... [17.0V]
TYPE B NEAR
Sets the near end voltage of [TYPE B]. (Can be adjusted in 0.1 V units.)
[11.0V] ... [13.4V] ... [15.0V]
TYPE B END
Sets the end voltage of [TYPE B]. (Can be adjusted in 0.1 V units.)
[11.0V] ... [12.9V] ... [15.0V]
BAT STAT NEAR
Sets the near end percentage of [BAT STAT].
[4%], [5%] - [10%] (by units of [1%]), [12%] - [20%] (by units of [2%])
f
When the battery charge level percentage cannot
be detected, this will follow the near end voltage
value set in [TYPE A].
f
When the battery charge level percentage cannot
be detected, this will follow the near end voltage
value set in [TYPE A].
BAT STAT END
Sets the end percentage of [BAT STAT END].
[1%] - [10%] (by units of [1%])
f
When the battery charge level percentage cannot
be detected, this will follow the end voltage value
set in [TYPE A].
f
When using a battery which displays battery
charge level by units of 10%, end is determined
only in two stages: when it is set to [1%] to [5%],
or when it is set to [6%] to [10%].
NEAR END CANCEL
Sets the cancelation of battery near end warning.
[ON], [OFF]
f
When this item is set to [ON], flashing of the warning lamp and tally lamp can be
stopped by pushing the <DISP/MODE CHK> switch towards the <CHK> side.
indicates factory setting values.