Troubleshooting
Problem
Causes
Solution
Have the telescopic pole replaced by an
authorized service centre.
The buckle is damaged.
The circuit fails or the fuse is broken down.
Send your product to an authorized service
centre for repair.
The product produces
no steam or irregular
steam.
The iron head is not fully heated.
Wait until the “ ” indicator stops flashing
before use.
The lock button on the telescopic pole is not
locked.
Lock the lock button securely.
The hose is bent and thus the water cannot
smoothly run through it.
Ensure the hose is not bent.
The garment is too heavy.
Lighten the weight loaded to the hanger fixer
(less than 3 k
g
).
The power plug is not inserted or the power
button is not pressed.
Insert the power plug and press the power
button.
The water tank is not installed correctly onto
the power base.
Attach the water tank onto the power base
correctly.
Fill the water tank with water as instructed.
The water tank is empty or the water level is
lower than the bottom of the water level window.
Condensate water produced from steam
remains in the hose.
Lift up the iron head vertically and straighten the
hose, to make condensate water flow back.
The power plug is not inserted, the power button
is not pressed or the steam level is not set
properly.
Insert the power plug, press the power button
and set the steam level to any level other than
“ ”.
Troubleshooting
Send your product to an authorized service
centre for repair.
The problem persists even after you have followed the above solutions.
Scale appears on the
soleplate.
Tap water may be polluted by the rusted water
pipe, so the steam ejected from the steam vents
may produce scale.
Fill the water tank with pure water. After the
product is powered on and the steam function is
turn on, press and rub the soleplate hard with a
wet cloth placed on a flat surface until the scale
is cleaned.
Problem
Causes
Solution
The power base
makes a noise.
Fill the water tank (by referring to “Filling the
water tank”).
When the water tank is empty, the water pump
will run idle, thus making a noise.
Attach the water tank onto the power base
correctly.
The water tank is not installed correctly onto the
power base.
Steam is ejected from
the bottom of the
power base.
The hose is bent and thus the steam cannot
smoothly run through it.
Ensure the hose is not bent.
The product cannot
be powered on.
The product is
powered off and the
steam stops.
The product is tilted or is placed on an unstable
place, which triggers the auto power off when
tilting function to turn the power off.
Make sure the power base is placed on a stable
and flat surface.
20
English
The soleplate does
not heat up.
The telescopic pole
slips down.
The water inlet cap of the water tank is loose.
Tighten the water inlet cap.
The water tank is broken.
Have the water tank replaced by an authorized
service centre.
The inner pipe is loose or damaged.
Send your product to an authorized service
centre for repair.
Water leaks out from
the power base.
21
English
Water leaks out from
the soleplate.
The circuit fails or the fuse is blown.
Send your product to an authorized service
centre for repair.
Wait until automatic cleaning has completed.
The automatic cleaning function is active.