18
5 Test Mode
5.1.
Component test procedure
5.1.1.
High voltage transformer
1. Remove connections from the transformer terminals and
check continuity.
2. Normal (cold) resistance readings should be as follows:
Secondary winding Approx. 80
Ω
-120
Ω
Filament winding Approx. 0
Ω
Primary winding Approx. 0
Ω
-3
Ω
5.1.2.
High voltage capacitor
1. Check continuity of capacitor with meter on highest OHM
scale.
2. A normal capacitor will show continuity for a short time,
and then indicate 9M
Ω
once the capacitor is charged.
3. A shorted capacitor will show continuous continuity.
4. An open capacitor will show constant 9M
Ω
.
5. Resistance between each terminal and chassis should be
infinite.
5.1.3.
Magnetron
Continuity checks can only indicate an open filament or a
shorted magnetron. To diagnose for an open filament or
shorted magnetron.
1. Isolate magnetron from the circuit by disconnecting the
leads.
2. A continuity check across magnetron filament terminals
should indicate one ohm or less.
3. A continuity check between each filament terminal and
magnetron case should read open.
Содержание NE-2153-2EYG
Страница 3: ...3 3 Location of Controls and Components 3 1 Outline diagram...
Страница 4: ...4...
Страница 5: ...5 4 Operating Instructions 4 1 Operation procedure...
Страница 6: ...6...
Страница 7: ...7...
Страница 8: ...8...
Страница 9: ...9...
Страница 10: ...10...
Страница 11: ...11...
Страница 12: ...12...
Страница 13: ...13...
Страница 14: ...14...
Страница 15: ...15...
Страница 16: ...16...
Страница 17: ...17...
Страница 22: ...22 6 2 Troubleshooting guide...
Страница 28: ...28 9 Wiring Connection Diagram NOTE When replacing check the lead wire colour as shown...
Страница 30: ...30 11 Exploded View and Replacement Parts List 11 1 Exploded view and parts list NE 2153 2EYG NE 2143 2EYG...