Panasonic NC-GK1WSN Скачать руководство пользователя страница 11

11

5 Troubleshooting Guide

5.1.

Check point

5.2.

Symptom and Trouble cause

5.2.1.

Hot water is not boiled.

Q-1 When "ON" does power switch.

 Check the conduction of the main body unit. : Conduction less / heater disconnection is thought about.

 Heater disconnection : Exchange of the main body unit.

Q-2 Even if "ON" does power switch, the power indicator lamp does not turn on.

 Check the conduction of power supply cord, the main body unit : Conduction less 

/Defectiveness of the power switch, disconnection of the power supply cord and the main body and the contact defectiveness of
the joint of the power base are thought about.

 The main body and the contact of the joint of the power base : Exchange of the main body unit.

 Poor in power supply cord disconnection and the main body and the contact of the joint of the power base. : Exchange of the

power base.

5.2.2.

Even if hot water is boiled, it is not cut off.

Q-1 Even if "ON" does power switch. (Hot water is boiled.)

 The power switch does not become "OFF" turns on.

 Exchange of the main body unit.

5.2.3.

Hot water is not sometimes boiled.

Q-1 It is not sometimes heated with time when hot water is boiled in a state of power switch "ON".

 With power switch as "ON", Check conduction while investing the main body on the power bade in right and left: Poor contact

of the joint of the power base is regarded as the main body unit.

 The defectiveness of the joint of the main body and the power base: Exchange of the main body or the power base.

Q-2 When hot water is boiled in power switch "ON", it is not sometimes heated.

 Twist power supply cord and, with power switch as "ON", check conduction: When poor conduction is sometimes caused,

poor power supply cord is thought about.

 Defectiveness of the power supply cord: Exchange of the power base.

Содержание NC-GK1WSN

Страница 1: ...Specifications 3 3 Installation Instructions 4 3 1 Partts Names and Handling Instructions 4 4 Operating Instructions 5 4 1 How to Use 5 4 2 How to Clean 7 4 3 Troubleshooting 8 4 4 Safety Precations 10 5 Troubleshooting Guide 11 5 1 Check point 11 5 2 Symptom and Trouble cause 11 6 Schematic Diagram 12 6 1 Model NC GK1 12 7 Exploded View and Replacement Parts List 13 7 1 Part Location 13 7 2 Repla...

Страница 2: ...2 1 Safety Precautions ...

Страница 3: ...3 2 Specifications ...

Страница 4: ...4 3 Installation Instructions 3 1 Partts Names and Handling Instructions ...

Страница 5: ...5 4 Operating Instructions 4 1 How to Use ...

Страница 6: ...6 ...

Страница 7: ...7 4 2 How to Clean ...

Страница 8: ...8 4 3 Troubleshooting ...

Страница 9: ...9 ...

Страница 10: ...10 4 4 Safety Precations ...

Страница 11: ...tact of the joint of the power base Exchange of the power base 5 2 2 Even if hot water is boiled it is not cut off Q 1 Even if ON does power switch Hot water is boiled The power switch does not become OFF turns on Exchange of the main body unit 5 2 3 Hot water is not sometimes boiled Q 1 It is not sometimes heated with time when hot water is boiled in a state of power switch ON With power switch a...

Страница 12: ...12 6 Schematic Diagram 6 1 Model NC GK1 ...

Страница 13: ...13 7 Exploded View and Replacement Parts List 7 1 Part Location 1 3 2 ...

Страница 14: ...s use only manufacturer s specified parts Please order Individual box ten by a unit Safety Ref No Part No Part Name Description Pcs Set Remarks PARTS LIST 1 APA40T674 W0S Main body unit 1 2 APB96 674 00U Mesh filter 1 3 APC78T674 W0S Power base 1 PACKING SPECIFICATIONS APZ01T674 W0U Individual box 1 with POS Label APZ62 674 00S Cushion set 1 APZ05J674 Operating instructions 1 ...

Страница 15: ...15 7 3 Packing Instruction Operating Instructions ...

Отзывы: