No. SX-DSV02829 -
54-
4-7 Linear motor/feedback scale setting
The MINAS-A5BL series requires you to set up the linear motor/feedback scale to be connected.
Follow the procedures below to set up the linear motor/feedback scale.
■Procedures
1. Set up linear motor/feedback scale parameter
(1) Linear motor (motor type, Inertia, toruqe, etc.)
Feedback scale (resolution, etc.)
Linear type
4-7-1-1
Rotary type
4-7-1-2
(2) Feedback scale
A/B phase
4-7-1-3
Serial increment
Serial absolute
(3) Pole position estimation
CS signal
4-7-3-1
Pole position estimation
4-7-3-2
Pole position recovery
4-7-3-3
2. Set up current gain
(A) Theoretical value
calculation based on
parameters
4-7-2
(B) Use automatic setting tool
4-7-4
3. Set up feedback scale/CS signal direction
(A) Manual setting
Scale
4-7-1-4
(B) Use automatic setting tool
4-7-4
CS signal
4-7-3-1
■Cautions
When the power is turned on at factory defaults, Err60.0 “Motor setting error protection” occurs. This is because the
linear motor/feedback scale is not yet set up.
When the installation condition is changed, such as when a linear motor or feedback scale is exchanged,
follow the procedures above to configure the setting again.
R1.00
Motor Business Unit, Panasonic Corporation