No. SX-DSV02829 -
35-
4-1 Operation direction setup
As opposed to position instructions / speed instructions / Torque instructions, and each offset,
Polarity (Operation
direction) can be set up.
In MINAS-A5BL series, a setup of the hand of cut by parameter Pr0.00 (Operation direction) has not corresponded,
the hand of cut is set up by object 607Eh (Polarity) specified to CoE (CiA402).
Please refer to section 6-9-4 "3) Polarity(607Eh)" of Technical Document "EtherCAT Communication
Specifications" (SX-DSV02830) for details of object 607Eh (Polarity).
Setting value
Description
0
No reverse of sign of torque, velocity, position
224
Reverse of sign of torque, velocity, and position possible
Other than above
Not supported (Do not set)
In addition, object 607Eh (Polarity) is not what replaced parameter Pr0.00 (hand-of-cut setup) as it was, It becomes
effective when performing the following data transfer between a CoE (CiA402) process division and a motor control
process division.
<
Instructions / setting > - 607Ah(Target position)
- 60B0h(Position offset)
- 60FFh(Target velocity)
- 60B1h(Velocity offset)
- 6071h(Target torque)
- 60B2h(Torque offset)
<Monitor > - 6062h(Position demand value)
- 6064h(Position actual value)
- 606Bh(Velocity demand value)
- 606Ch(Velocity actual value)
- 6074h(Torque demand)
- 6077h(Torque actual value)
<
External input > - 60FDh-00h(Digital input) is bit1(positive limit switch(POT))
- 60FDh-00h(Digital input) is bit0(negative limit switch(NOT))
Data other than the above, for example,
such as data on setup support tool PANATERM, are set to fixed values
regardless of the setting of 607Eh (Polarity), where the positive direction is the direction in which the feedback
scale count is counted up positively. With regard to POT and NOT during operation from PANATERM such as
trial operation, frequency characteristics analysis, POT is enabled when the operation is made in the direction in
which the feedback scale count is counted up positively.
When 607Eh(Polarity) is setting to reverse of sign, When you perform a test run etc., please be careful of the logic
of the ban on a drive.
PANATERM
607Eh-00h
Polarity
60FDh(POT/NOT)
Pr0.00
(Not supported)
=
not reversed
The positive
direction is the
direction in which
the feedback scale
count is counted up
positively.
Motor control Processing
CoE(CiA402) Processing
Instructions / setting such as 607Ah
External input (POT/NOT)
Monitor such as 6062h
Instructions / setting other than 607Ah etc.
Monitor other than 6062h etc.
R1.00