3 Troubleshooting Guide

CONDITION

CHECK POINT

METHOD OF INSPECTION

TRANSACTION

Motor fails to rotate
(no noise is heard at all)

Power supply cord 

Check power supply cord continu-
ity.

If there is no continuity, replace the 
cord reel patition unit.

Fuse of P.C.B. Ass’y
(250V, 10A)

Check fuse continuity.

If there is no continuity, replace 
P.C.B. Ass’y.

Motor continuity

Check the conduction between the 
terminals of the motor.

If there is no continuity, replace the 
or motor.

ON/OFF 

Switch

Check continuity across switch
connections

If there is no continuity, replace
P.C.B. Ass’y.

P.C.B. Ass’y

Check the internal parts for any-
thing unusual. (burn-out, melt-
down, etc.)

If anything is found unusual, 
replace the P.C.B. assembly with 
new one.

Motor runs but there is no suction Hose or Suction inlet, Extension 

wand and nozzle

Check whether or not the specified 
components are clogged with for-
eign substances.

If there is any blockage, remove it.

Dust bog / Secondary filter

Check if dust bag is full or Second-
ary filter is choked up.

If dust bag is foll, replace with a 
new one. If Secondary filter is 
choked up, remove and clean it out 
or replace.

Noise or vibration

Motor fan

Check dust accumulated in motor 
fan (it could happen if the vacuum 
cleaner has been used without cen-
tral filter).

If there is dust accumulated in the 
motor fan, replace the motor and 
check filter condition. (never try to 
dismantle the motor fan)

The motor output cannot be 
changed.
(The motor rotation does not 
change.)
(The motor always rotates at full 
speed.)

Output controller

Adjust the output controller and 
check whether or not the resistance 
varies.

If the resistance value does not 
change, then replace the P.C.B. 
ass'y.

P.C.B. ass’y

Check whether or not T1 and T2 of 
the Triac on the P.C.B. ass'y are 
short-circuited.

If they are short-circuited, then 
replace the P.C.B. ass'y.

Содержание MC-CG383-RC79

Страница 1: ...cation of Controls and Components 3 3 Troubleshooting Guide 5 4 Disassembly and Assembly Instructions 6 4 1 Dust box cover assembly removal 6 4 2 Separate the upper and lower body units 6 4 3 Removal of the cord reel U 7 4 4 Removal of the P C B ass y and motor 8 5 Wiring Connection Diagram 10 6 Exploded View and Replacement Parts List 11 6 1 EXPLODED VIEW ATTACHMENTS 11 6 2 PARTS LIST ATTACHMENTS...

Страница 2: ...MC CG383K Power source 230 V 50 Hz 230 240 V 50 Hz Input power MAX 1800 W Input power Nominal 1500 W 1400 1500 W Power control O Extension wand Metal x 2 Telescopic Dimensions WxLxH mm 240x350x250 Net weight 3 8kg Multipurpose accessory O ...

Страница 3: ...3 2 Location of Controls and Components ...

Страница 4: ...4 ...

Страница 5: ...k whether or not the specified components are clogged with for eign substances If there is any blockage remove it Dust bog Secondary filter Check if dust bag is full or Second ary filter is choked up If dust bag is foll replace with a new one If Secondary filter is choked up remove and clean it out or replace Noise or vibration Motor fan Check dust accumulated in motor fan it could happen if the v...

Страница 6: ... unit is available as service parts Replace the overall section with a new wired unit 3 Pull out and or insert the fastening terminal without twisting it 4 1 Dust box cover assembly removal 1 Insert a flat blade screwdriver between the dust box lid and its fitting section on the body and move it in the direc tion of the arrow to remove the dust box lid from the body 4 2 Separate the upper and lowe...

Страница 7: ... the cord reel partition ass y from the lower body 3 Remove the two lead wires connected to the cord reel partition ass y a Remove the terminal connected to the P C B U b First remove either of the terminals connected to the switch Caution Pull out the fastening terminal without twisting it Pull out by holding down the section indicated by an arrow ...

Страница 8: ...ng Caution for re assembling There are four pre wind ings 6 Remove the screw fixing the cord reel U and the body partition U 7 Remove the cord reel U 4 4 Removal of the P C B ass y and motor 1 Remove the motor case U with the motor and the P C B ass y fitted from the lower body 2 Remove the P C B ass y from the motor case U ...

Страница 9: ...is removed simultaneously 5 Remove the noise supporessor motor support rubber rear and motor support rubber front Precautions for re assembly Tape is pasted on the lead wire terminals of compo nents on the P C B Ass y The tape must not be removed when components are replaced If the tape is removed by mistake then use tape for servicing Servicing component part number AMC56L 1800E Component name Ga...

Отзывы: