23
7.2.
When Replacing the Main P.C.B.
After replacing the MAIN P.C.B., be sure to achieve adjustment.
The adjustment instruction is available at “software download” on the “Support Information from NWBG/VDBG-AVC” web-site in
“TSN system”, together with Maintenance software.
7.3.
Service Position
This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.
Table S1 Extension Cable List
CAUTION-1. (When servicing FLASH TOP P.C.B.)
1. Be sure to discharge the capacitor on FLASH TOP P.C.B..
Refer to “HOW TO DISCHARGE THE CAPACITOR ON FLASH TOP P.C.B.”.
The capacitor voltage is not lowered soon even if the AC Cord is unplugged or the battery is removed.
2. Be careful of the high voltage circuit on FLASH TOP P.C.B..
3. DO NOT allow other parts to touch the high voltage circuit on FLASH TOP P.C.B..
No.
Parts No.
Connection
Form
1
RFKZ0477
FP9001 (MAIN) - CCD UNIT
45PIN 0.3 FFC
2
RFKZ0416
FP9002 (MAIN) - LENS UNIT
41PIN 0.3 FFC
3
RFKZ0416
FP9003 (MAIN) - LCD UNIT
41PIN 0.3 FFC
4
RFKZ0545
PP9001 (MAIN) - PS8001 (FLASH TOP)
34PIN B to B
Содержание LUMIX DMC-ZX3EB
Страница 13: ...13 4 Specifications...
Страница 19: ...19 3 Error Code List The error code consists of 8 bits data and it shows the following information...
Страница 27: ...27 Fig D6 8 3 6 Removal of the Flash Top P C B and Speaker Fig D7...
Страница 28: ...28 Fig D8 8 3 7 Removal of the Lens Unit Fig D9...
Страница 30: ...30 Fig D13 8 3 11 Removal of the Battery Case Unit Fig D14...
Страница 65: ...S7 2 Packing Parts and Accessories Section 1 S 17 201 204 205 206 214 200 215 202 208 210 213 212 218 211...