10 Measurements and Adjustments
10.1. Matrix Chart for Replaced Part and Necessary Adjustment
The relation between Replaced part and Necessary Adjustment is shown in the following table.
When concerned part is replaced, be sure to achieve the necessary adjustment(s).
As for Adjustment condition/procedure, consult the “Adjustment method” which is available in Adjustment software.
NOTE:
After adjustments have been terminated, make sure to achieve “INITIAL SETTINGS”.
After updates it to the latest firmware, the adjustment is executed.
*1 NOTE: (After exchange the Front-mount unit)
• Execute the resolution inspection by the comparison with the standard model (DMC-G1K etc.: operates normal).
• Refer to the adjustment method in the adjustment software for details.
*2 NOTE: (When exchange the MAIN P.C.B.)
• Correspond by either the following when exchange the MAIN P.C.B. unavoidably by destruction and damage etc. of MAIN
P.C.B..
1. When it can turn on power, and the adjustment software can communicate with the camera body:
• Before replacing, proceed the Flash-ROM (IC6003) data backup from the unit.
After replacing, overwrite the Flash-ROM (IC6003) data with backup data from the unit.
After that, proceed the main body adjustment.
2. When it cannot turn on power, or the adjustment software cannot communicate with the camera body:
• The readjustment of Front-mount unit etc. are necessary.
• Refer to the adjustment method in the adjustment software for details.
*3 NOTE: (When AWB adjustment)
• After change to WB adjustment mode for service with software, the adjustment is executed.
After adjusting the AWB adjustment, to cancel the WB adjustment mode for service.
• Details, refer to the adjustment method in the adjustment software.
*4 NOTE: (About the G sensor adjustment)
• Offset adjustment for built in tilt sensor display.
• Refer to the adjustment method in the adjustment software for details.
*5 NOTE: (About Front-mount unit adjustment data writing)
• After exchange Front-mount unit for service, write data on the label of body cap.
• Label data doesn’t have the electronic 1st curtain shutter adjustment value.
• Refer to the adjustment method in the adjustment software for details.
Содержание LUMIX DMC-GM1KP
Страница 20: ...20...
Страница 21: ...21...
Страница 22: ...22 4 2 Lens...
Страница 24: ...24 5 2 Lens...
Страница 27: ...27 7 Troubleshooting Guide 7 1 Checking Method of Body and Interchangeable Lens...
Страница 28: ...28...
Страница 29: ...29...
Страница 30: ...30...
Страница 31: ...31...
Страница 40: ...40 9 1 3 1 Removal of the Rear Case Unit Fig D1 Fig D2 9 1 3 2 Removal of the LCD Unit Fig D3...
Страница 41: ...41 Fig D4 9 1 3 3 Removal of the Main P C B Fig D5...
Страница 42: ...42 Fig D6 Fig D7...
Страница 43: ...43 Fig D8 9 1 3 4 Removal of the Mount and Lens Ring Fig D9...
Страница 44: ...44 Fig D10 9 1 3 5 Removal of the Front Grip Sheet R Fig D11...
Страница 45: ...45 Fig D12 9 1 3 6 Removal of the Front Grip Sheet L Fig D13 Fig D14...
Страница 46: ...46 9 1 3 7 Removal of the Top Case Unit Fig D15 Fig D16...
Страница 47: ...47 9 1 3 8 Removal of the Flash Base Unit Fig D17 9 1 3 9 Removal of the Flash Unit Fig D18...