21
7.2.
When Replacing the Main P.C.B.
After replacing the MAIN P.C.B., be sure to achieve adjustment.
The adjustment instruction is available at “software download” on the “Support Information from NWBG/VDBG-AVC” web-site in
“TSN system”, together with Maintenance software.
7.3.
Service Position
This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.
Table S1 Extension Cable List
CAUTION-1. (When servicing FLASH TOP P.C.B.)
1. Be sure to discharge the capacitor on FLASH TOP P.C.B..
Refer to “HOW TO DISCHARGE THE CAPACITOR ON FLASH TOP P.C.B.”.
The capacitor voltage is not lowered soon even if the AC Cord is unplugged or the battery is removed.
2. Be careful of the high voltage circuit on FLASH TOP P.C.B..
3. DO NOT allow other parts to touch the high voltage circuit on FLASH TOP P.C.B..
No.
Parts No.
Connection
Form
1
RFKZ0494
FP9001 (MAIN) - CCD UNIT
45PIN 0.3 FFC
2
RFKZ0416
FP9002 (MAIN) - LENS UNIT
41PIN 0.3 FFC
3
RFKZ0416
FP9003 (MAIN) - LCD UNIT
41PIN 0.3 FFC
4
RFKZ0418
PP9001 (MAIN) - PS8001 (FLASH TOP)
30PIN B to B
5
RFKZ0553
PS9001 (MAIN) - PP9501 (SUB OPERATION)
16PIN B to B
Содержание LUMIX DMC-FS11EB
Страница 13: ...13 4 Specifications ...
Страница 17: ...17 3 Error Code List The error code consists of 8 bits data and it shows the following information ...
Страница 24: ...24 Fig D2 8 3 2 Removal of the Sub Operation P C B Fig D3 8 3 3 Removal of the LCD Unit Fig D4 ...
Страница 25: ...25 Fig D5 8 3 4 Removal of the Top Operation Unit Fig D6 8 3 5 Removal of the Flash Top P C B Fig D7 ...
Страница 26: ...26 Fig D8 8 3 6 Removal of the Lens Unit Fig D9 8 3 7 Removal of the Main P C B Fig D10 ...
Страница 58: ...S7 2 Packing Parts and Accessories Section 1 S 17 201 204 205 206 214 200 215 202 208 210 213 212 218 211 ...