2-1-5 Installation of the Controller
The installation method of the controller is common to LP-400, LP-V and LP-W series.
⿎
Installation Method and Direction
• The controller can be fixed from the bottom or side surfaces with M5 screw at four locations.
•
When the side surface is the mounting surface, set the key-switch side down.
•
For the installation dimension, refer to “Controller” (P.42) for LP-400series, “Controller” (P.44) for LP-V/LP-W series.
•
The inserting length of the screw shall be 4 mm to 6 mm.
•
Tightening torque: 2.0 N·m or less.
•
The rubber feet can be mounted either on bottom or side face. For the rubber feet installation, use the attached M5
depth 15 mm screws.
M5 Screw
M5 Screw
⿎
Installation Space
For the appropriate air cooling, provide space around the device as shown in the following figure.
150mm
50mm
50mm
200mm
q
w
q
Intake air
w
Exhaust
Notice
•
Ensure the minimum bent radius of each cable.
• Please install not to bar the flow of air cooling.
•
Installing near a heating element could be over ambient temperature and cause malfunction of the product.
•
Check the length of the screw and install it. Using improper screws and forcibly tightening them might damage the
product.
ME-LP400V-OP-6
Содержание LP-V Series
Страница 11: ...11 MEMO ME LP400V OP 6 ...
Страница 32: ...32 1 Product Overview ME LP400V OP 6 ...
Страница 58: ...2 Installation and Connection ME LP400V OP 6 ...
Страница 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Страница 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Страница 146: ...146 Symbol ME LP400V OP 6 ...
Страница 271: ...271 MEMO ME LP400V OP 6 ...
Страница 272: ...Maintenance ME LP400V OP 6 ...
Страница 291: ...Troubleshooting ME LP400V OP 6 ...
Страница 308: ...Appendix ME LP400V OP 6 ...
Страница 328: ...Index ME LP400V OP 6 ...
Страница 333: ...No 9000 0062 14V ...
Страница 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...