39
Item
Model
LP-V10U
LP-V15U
LP-W052U
Required time for laser
pumping
Approx. 20 sec.
Approx. 15 sec.
Power voltage
90V to 132V AC or 180V to 264V AC (including ±10% voltage fluctuations) *8
Frequency: 50/60 Hz
Power
consumption *9
100V AC
390VA or less
310VA or less
200V AC
420VA or less
360VA or less
Grounding method
Head: Direct Earth, Controller: Direct Earth
Cooling method
Head: Forced air-cooling, Controller: Forced air-cooling
Ambient temperature *10
0 °C to +40 °C
Ambient temperature for
storage *10
-10 °C to +60 °C
Ambient humidity *10
35 to 85%RH
Overvoltage category
Ⅱ
Pollution degree
2
Use location
Indoor; at an altitude of 1000 m or below
Fiber cable length
4.5 m, Minimum bent radius 60 mm
Installation
direction
Head
Omnidirectionally
Controller
Vertically or Horizontally
Weight
Head
Approx. 9 kg
Approx. 10 kg
Approx. 9 kg
Controller
Approx. 22 kg
Battery
(Embedded
in product)
Type
Graphite Fluoride Lithium Battery
Model
BR-1 / 2AAC2P
Quantity
1 piece
Weight
Approx. 9.5 g
*1 : Average output power from the laser oscillator at delivery time with the laser power setting 100.
*2 : Work distance has an individual error of /-2 mm per product.
*3 :
The descried values are available ranges for configuration. The marking quality may vary depending on materials of
marking objects and marking conditions.
*4 : Depending on the marking data, the available scan speed might be limited in case the continuous marking more than
1 minute with high scan speed is set.
*5 : For using SQRC, an optional software is needed. SQRC marking function is available only for use in Japan.
*6 :
VEC is a graphic file format dedicated for the laser marker. To use HPGL, BMP or JPEG files, convert them to VEC
format with the attached “Logo Data Conversion software”. To use AI or EPS files, convert them to VEC format with
the attached software “ExportVEC”.
*7 : Check the performance and operation before use. USB media with security features cannot be used.
*8 : The power supply voltage switches automatically.
*9 : The typical value of the inrush current at system startup is 40A. (Duration time is 10 ms or less.)
*10 :
This specification is applied to both controller and head. No condensation and freezing shall be allowed. If there is
a gap between the stored temperature and operating temperature, make sure to have the product get used to the
operating ambient temperature gradually prior to use to prevent the dew condensation.
ME-LP400V-OP-6
Содержание LP-V Series
Страница 11: ...11 MEMO ME LP400V OP 6 ...
Страница 32: ...32 1 Product Overview ME LP400V OP 6 ...
Страница 58: ...2 Installation and Connection ME LP400V OP 6 ...
Страница 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Страница 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Страница 146: ...146 Symbol ME LP400V OP 6 ...
Страница 271: ...271 MEMO ME LP400V OP 6 ...
Страница 272: ...Maintenance ME LP400V OP 6 ...
Страница 291: ...Troubleshooting ME LP400V OP 6 ...
Страница 308: ...Appendix ME LP400V OP 6 ...
Страница 328: ...Index ME LP400V OP 6 ...
Страница 333: ...No 9000 0062 14V ...
Страница 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...