284
7.
Check the measurement results of the power
meter. If the power decays lower than the
default status, correct the laser power setting
value using the “System Offset” of the
“ENVIRON.” screen.
Setting range of laser power correction: 50 to 200 [%]
Reference
•
The laser power offset refers to the function to
correct not the maximum laser power [W] value, but
the laser power setting value.
•
If the value of “Laser power correction” × “laser
power” is equal to or larger than 100, the setting will
be “100”.
Notice
•
If the power decays more than 20%, compared to the default setting, the laser oscillator needs maintenance. Contact our
sales office or representatives.
Galvano scanner
Galvano scanner is a scanner for radiating the laser beam along the coordinates of marking data.
The galvano scanner scans the setting data by controlling the angle of galvano mirror mounted onto the axis of rotation of
motor with two axes to create characters and graphics for marking and processing.
⿎
Effect from deterioration
Uneven wear may occur on the bearing inside the galvano scanner depending upon marking frequency and conditions. If
uneven wear develops, accurate reproducing may become difficult, resulting in skewness or misalignment of marking lines.
⿎
Replacement interval
•
Deterioration in quality of marking and processing (Characters crushed, streaking and density reduction of the marking,
incomplete processing) is observed.
•
Alarm for galvanometer error occurred.
• Galvano scanner has been used for almost five years.*
* The replacement interval may differ depending on the usage environment and marking conditions.
⿎
Replacement method
Our service representative handles the maintenance and replacement. Contact our sales office.
ME-LP400V-OP-6
Содержание LP-V Series
Страница 11: ...11 MEMO ME LP400V OP 6 ...
Страница 32: ...32 1 Product Overview ME LP400V OP 6 ...
Страница 58: ...2 Installation and Connection ME LP400V OP 6 ...
Страница 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Страница 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Страница 146: ...146 Symbol ME LP400V OP 6 ...
Страница 271: ...271 MEMO ME LP400V OP 6 ...
Страница 272: ...Maintenance ME LP400V OP 6 ...
Страница 291: ...Troubleshooting ME LP400V OP 6 ...
Страница 308: ...Appendix ME LP400V OP 6 ...
Страница 328: ...Index ME LP400V OP 6 ...
Страница 333: ...No 9000 0062 14V ...
Страница 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...