239
4-14 Image Display Screen
This is a screen for checking the image of character string/logo set in the character setting or condition setting.
Image checking before marking is effective to reduce any errors.
Position adjustment is also possible on this screen. Adequate position can be set by checking the image.
4-14-1 Image Display
1
3
4
5
6
7
9
8
2
10
11
Description
1
Image Screen :
Image-displays the marking content set previously.
2
Magnification :
Sets the magnification ratio of the image display.
Press the numeric part of the magnification to set the arbitrary magnification on the screen.
3
Image Display Zoom-in/Zoom-out :
The image can be zoomed in and out by 18 steps.
4
Center of Image Display :
Set the origin center to image display position.
5
Image Display Position :
Indicates where the current image is in the marking field.
6
Shift Display Position :
Shifts image display part up and down, left and right. Pressing arrow shifts the image display part.
7
Area No. *1 :
Displayed when marking on-the-fly is set in “Trigger setting”.
It indicates the order of the marking field for the concatenated marking to flying object.
Press [+] or [-] to select the desired area number. The image corresponding to the selected Area No. is displayed.
Refer to “Concatenated Marking Setting” (P.226).
8
Auxiliary Line *1 :
Auxiliary line used for setting marking to flying object.
Refer to “Concatenated Marking Setting” (P.226).
9
Object (Adjustment Object) :
Select the object to be fine adjusted.
The data which shows in red character or image on the window is the selected object.
ME-LP400V-OP-6
Содержание LP-V Series
Страница 11: ...11 MEMO ME LP400V OP 6 ...
Страница 32: ...32 1 Product Overview ME LP400V OP 6 ...
Страница 58: ...2 Installation and Connection ME LP400V OP 6 ...
Страница 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Страница 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Страница 146: ...146 Symbol ME LP400V OP 6 ...
Страница 271: ...271 MEMO ME LP400V OP 6 ...
Страница 272: ...Maintenance ME LP400V OP 6 ...
Страница 291: ...Troubleshooting ME LP400V OP 6 ...
Страница 308: ...Appendix ME LP400V OP 6 ...
Страница 328: ...Index ME LP400V OP 6 ...
Страница 333: ...No 9000 0062 14V ...
Страница 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...