217
4-11-2 Detail Adjustment (Laser Setting)
1
5
2
6
3
7
4
The following fine adjustments are allowed.
Description
1
Edge (Edge Adjustment) :
Adjust the edge of line in the character to be marked.
Though setting a small value here can shorten the marking time, the line edge becomes dull.
Setting large value makes the edge thick.
Setting Range
0 to 100
Initial Value
0
Round Edge
Dark (Deep) Edge
Proper
Small
Large
2
Curve (Curve Adjustment) :
The shape of curve line in the character to be marked is adjusted.
Though setting a small value here can shorten the marking time, the curve line is distorted.
Setting large value makes the edge thick.
Setting Range
0 to 100
Initial Value
0
Curve Line Distorted
Dark (Deep) Line
Proper
Small
Large
3
Waiting Time (Waiting Time Adjustment) :
Adjusts the waiting time for starting radiation at the start point of each line.
Apply to all line segment.
Setting a large value improves the marking disorder.
Too large value, however, makes the marking time longer.
Setting Range
0 to 100
Initial Value
0
ME-LP400V-OP-6
Содержание LP-V Series
Страница 11: ...11 MEMO ME LP400V OP 6 ...
Страница 32: ...32 1 Product Overview ME LP400V OP 6 ...
Страница 58: ...2 Installation and Connection ME LP400V OP 6 ...
Страница 77: ...3 Basic Operation Procedure ME LP400V OP 6 ...
Страница 121: ...4 Description of Operation Screen ME LP400V OP 6 ...
Страница 146: ...146 Symbol ME LP400V OP 6 ...
Страница 271: ...271 MEMO ME LP400V OP 6 ...
Страница 272: ...Maintenance ME LP400V OP 6 ...
Страница 291: ...Troubleshooting ME LP400V OP 6 ...
Страница 308: ...Appendix ME LP400V OP 6 ...
Страница 328: ...Index ME LP400V OP 6 ...
Страница 333: ...No 9000 0062 14V ...
Страница 334: ... Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 14V ...