185
Description
5
Line Interval :
Specifies the radius between the lines.
Setting Range
0.000 to 90.000 mm
(LP-V10)
0.000 to 110.000 mm
(LP-430 / LP-420 / LP-410)
0.000 to 160.000 mm
(LP-435 / LP-425 / LP-V15)
0.000 to 55.000 mm
(LP-431 / LP-421 / LP-411 / LP-W052)
6
Start Angle :
The starting position of the first marking character on the first line.
Setting Range
-180.00 to +180.00 degree
7
Character Interval Angle :
Angle between two adjacent characters.
Setting Range
-180.00 to +180.00 degree
Character Interval Angle
Radius
Center Position (X, Y)
Start Angle
Line Interval
Radius
Character Interval Angle
Radius
Center Position (X, Y)
Start Angle
Line Interval
Radius
Fan-like “+”
(Origin of character string for left justification)
Fan-like “-”
(Origin of character string for left justification)