Connectable code reader
This product can be connected with a code reader that can be operated in the RS-232C communication settings described
below.
Communication settings (for code reader linkage control)
Communication settings for use of the code reader linkage function are listed below.
Specify the code reader communication settings according to this setting.
Item
RS-232C communication specifications (for code reader linkage control)
Synchro system
Start-stop method
Communication type
Full-duplex transmission
Baud rate
1200 / 2400 / 4800 / 9600 / 19200 / 38400 / 57600 / 115200 bps (initial setting: 9600 bps)
Data length
8-bit fixed
Stop bits
1-bit / 2-bit (initial setting: 1-bit)
Parity
None / Even / Odd (initial setting: None)
Flow control
None
Start code
None (fixed)
Check sum
None (fixed)
End code
CR (Fixed)
Reception timer
Timeout monitoring ON (10 sec)
ワㄐㄕㄊㄆ
• This does not guarantee the communication with all code readers. Check the performance and operation before use.
• To connect the RS-232C port with the code reader, the communication command control by RS-232C is disabled.
• The control is enabled only when the laser marker is in the remote or run status.
6-2-4 Preparation of readout code
String that can be transferred
To use the code reader linkage function, check that the readout bar code/2D code data to read satisfy the following
conditions.
• Generate code data by alphanumeric characters and symbols within the range of ASCII code 20(HEX) to 7E(HEX).
• To set the file number, specify it always with 4-digits.
• Do not contain two-byte characters and/or control codes in the code data.
• When two-byte “%” is used, replace the code data with the following characters.
Characters you want to use
Characters to replace with
%
%%
ンㄆㄇㄆㄓㄆㄏㄆ
• As long as the code data to read satisfy the above conditions, any code type can be used.
• If any character that is not supported is contained in the read code, data cannot be transferred to the laser marker
regardless of data extraction setting.
• For the list of ASCII codes, refer to “Serial Communication Command Guide”.
ME-LPRH-SM-3
Содержание LP-RH Series
Страница 19: ...1 Product Overview ME LPRH SM 3...
Страница 42: ...2 Laser Marker Installation ME LPRH SM 3...
Страница 68: ...3 Operation Method ME LPRH SM 3...
Страница 90: ...4 External Control Using I O ME LPRH SM 3...
Страница 138: ...5 External Control by Communication Commands ME LPRH SM 3...
Страница 147: ...6 Link Control with External Devices ME LPRH SM 3...
Страница 172: ...7 Maintenance ME LPRH SM 3...
Страница 201: ...Troubleshooting ME LPRH SM 3...
Страница 236: ...Index ME LPRH SM 3...
Страница 238: ...238 Test marking 69 82 TIMING IN 155 U Unit power cable 32 USB 38 39 64 W Warning 225 ME LPRH SM 3...
Страница 239: ......