6-1-5 Set the laser marker overall file conditions
Set the overall file conditions of the Laser Marker NAVI smart according to the type of the system to establish.
1.
Establish an online connection between your PC and the laser marking system.
2.
Go to the “Marking settings” screen and select “File settings” tab.
3.
Turn ON “Image checking before marking” and “Image
checking after marking” depending on the functions to
use.
ンㄆㄇㄆㄓㄆㄏㄆ
• When you use the link control with an image checker, the
following functions are not available.
• “Continuous trigger” of trigger mode
• On-the-fly marking
• TARGET DETECTION IN of the I/O terminal
4.
Select the model of the image checker and application.
For image checking before marking:
• Model: PV230/PV200 (fixed)
• Application: Marking position correction (fixed)
For image checking after marking:
• Model: PV230/PV200, DataMan
• Application: Code checking, Character checking, Image capturing and inspection
ンㄆㄇㄆㄓㄆㄏㄆ
• The application of the image checking before marking is fixed to “Marking position correction”.
• For the image checking after marking, specify the type No. used for PV230/PV200 with an external device such as a
PLC.
• If you use DataMan for the image checking after marking, the application is fixed to “Code checking”.
• If you use PV200 for the image checking after marking, the application is fixed to “Image capturing and inspection”.
• If you use PV230 for code checking, the human readable text can be also checked with a code symbol.
5.
Set the TIMING IN signal input.
Set whether to use the TIMING IN signal as the operation
start method of each device for link control.
• Using TIMING IN signal: Input the operation trigger of
each device separately.
• Not using TIMING IN signal: Perform a set of link
controls by one marking trigger input.
Refer to “Details of TIMING IN signal” (P.155).
ME-LPRH-SM-3
Содержание LP-RH Series
Страница 19: ...1 Product Overview ME LPRH SM 3...
Страница 42: ...2 Laser Marker Installation ME LPRH SM 3...
Страница 68: ...3 Operation Method ME LPRH SM 3...
Страница 90: ...4 External Control Using I O ME LPRH SM 3...
Страница 138: ...5 External Control by Communication Commands ME LPRH SM 3...
Страница 147: ...6 Link Control with External Devices ME LPRH SM 3...
Страница 172: ...7 Maintenance ME LPRH SM 3...
Страница 201: ...Troubleshooting ME LPRH SM 3...
Страница 236: ...Index ME LPRH SM 3...
Страница 238: ...238 Test marking 69 82 TIMING IN 155 U Unit power cable 32 USB 38 39 64 W Warning 225 ME LPRH SM 3...
Страница 239: ......