144
5-3-2 Communication settings
Item
Ethernet communication settings
Communication protocol
TCP/IP
Standards
IEEE802.3 (10BASE-T) / IEEE802.3u (100BASE-TX)
Applicable cable
Category 5 or higher
Applicable HUB (or rooter)
10BASE-T / 100BASE-TX compatible
IP address
1.0.0.0 to 223.255.255.255 * (Initial value: 192.168.1.5)
Subnet mask
128.0.0.0 to 255.255.255.254 (Initial value: 255.255.255.0)
Default gateway
1.0.0.0 to 223.255.255.255 * (Initial value: 0.0.0.0 (Unspecified))
PC configuration software port
1025 to 65534, except 9090 (Initial value: 9093)
Command communication port
1025 to 65534, except 9090 (Initial value: 9094)
* Do not use “127” in the first octet.
ンㄆㄇㄆㄓㄆㄏㄆ
• The communication control of the laser marker through the Ethernet should be performed in a secure network settings.
• Even the IP Address and Subnet Mask values are within the configurable range, they may not be available depending
on the combination.
• For the details of the communication settings, refer to “3-4-3 General settings before external control” (P.86).
⿎
Ethernet communication settings for communication command control
Item
Ethernet communication settings
Start code *
ON (STX) / OFF (initial setting: STX)
Response data command * ON / OFF (initial setting: ON)
Response data sub
command *
Any single byte character of ASCII code from 01 (HEX) to 7F (HEX) can be specified.
• Initial setting of positive response code: A
• Initial setting of negative response code: E
• Initial setting of read request response code: A
Character code
ASCII code
Encoding for non-ASCII
characters *
Shift-JIS / GB 2312 / Latin-1 (initial setting: Shift-JIS)
Check sum
OFF
End code
CR
Reception timer
Timeout monitoring ON (10 sec.)
* If you select “LP-400/V compatible” for “Compatible mode” in the system settings of Laser Marker NAVI smart, the same
command format with the former models of LP-400/LP-V series is applied regardless these settings. For the details, refer
to the “Serial Communication Command Guide: LP-400/V compatible mode”.
ME-LPRH-SM-3
Содержание LP-RH Series
Страница 19: ...1 Product Overview ME LPRH SM 3...
Страница 42: ...2 Laser Marker Installation ME LPRH SM 3...
Страница 68: ...3 Operation Method ME LPRH SM 3...
Страница 90: ...4 External Control Using I O ME LPRH SM 3...
Страница 138: ...5 External Control by Communication Commands ME LPRH SM 3...
Страница 147: ...6 Link Control with External Devices ME LPRH SM 3...
Страница 172: ...7 Maintenance ME LPRH SM 3...
Страница 201: ...Troubleshooting ME LPRH SM 3...
Страница 236: ...Index ME LPRH SM 3...
Страница 238: ...238 Test marking 69 82 TIMING IN 155 U Unit power cable 32 USB 38 39 64 W Warning 225 ME LPRH SM 3...
Страница 239: ......