120
4-6-3 Marking trigger input (to static object): Single trigger
When the trigger mode is set to “single trigger” in the file settings, one lasing operation is executed by the edge of turning
on of TRIGGER IN (X5).
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON (Normal)
OFF (Error)
ON (Normal)
OFF (Error)
T1
T5
T4
T2
T1
T4
T6
T2
T1
T3
T3
T3
READY OUT (Y5)
TRIGGER IN (X5)
PROCESSING FAIL
OUT (Y12)
WARNING OUT (Y14)
ALARM OUT (Y15)
PROCESSING OUT
(Y10)
PROCESSING END
OUT (Y11)
Marking
interruption
Marking
interruption
LASING OUT (No.40)
Item
Time
Remarks
T1
2ms or more
Keep the ON status for 2ms or more.
T2
―
When TRIGGER IN (X5) is accepted, PROCESSING OUT (Y10) turns ON. The output time
of PROCESSING OUT (Y10) includes the trigger delay time, marking preparation time,
laser radiation time, and processing time after marking has completed.
T3
0 to 9999ms
When the trigger delay time is set in the selected file, trigger processing (lasing) operation
starts after the delay time.
T4
2 to 510ms
This is the output to notify that the marking trigger processing completed normally. This
is One-shot output. Set the output time on the system settings screen. There is a small
margin of error for the setting value.
T5
Approx. 3 sec.
It outputs a warning to notify that an invalid trigger was input when TRIGGER IN (X5) was
input during trigger processing. This is One-shot output. You can turn this warning off by
the settings.
T6
2 to 510ms
If the trigger processing was stopped by an alarm or a warning, PROCESSING FAIL OUT
(Y12) turns on during the one-shot output period. PROCESSING END OUT (Y11) will not
be output at this time.
ME-LPRH-SM-3
Содержание LP-RH Series
Страница 19: ...1 Product Overview ME LPRH SM 3...
Страница 42: ...2 Laser Marker Installation ME LPRH SM 3...
Страница 68: ...3 Operation Method ME LPRH SM 3...
Страница 90: ...4 External Control Using I O ME LPRH SM 3...
Страница 138: ...5 External Control by Communication Commands ME LPRH SM 3...
Страница 147: ...6 Link Control with External Devices ME LPRH SM 3...
Страница 172: ...7 Maintenance ME LPRH SM 3...
Страница 201: ...Troubleshooting ME LPRH SM 3...
Страница 236: ...Index ME LPRH SM 3...
Страница 238: ...238 Test marking 69 82 TIMING IN 155 U Unit power cable 32 USB 38 39 64 W Warning 225 ME LPRH SM 3...
Страница 239: ......