73
3-2-1 DIP switch setting
Set the operational options for the external control with the DIP switch equipped on the controller rear side.
ンㄆㄇㄆㄓㄆㄏㄆ
• The initial setting of all DIP switches is OFF.
• Turn OFF the power at DIP switch setting.
• For the details on DIP switch, refer to “2-2-3 DIP switch” (P.46).
1.
Turn OFF the power of laser marker.
2.
Remove the DIP switch cover on the rear of the controller.
ON
OFF
Rear of controller
DIP switch
3.
With DIP switch No. 2, select the control method, I/O or command
for some specific operations.
DIP switch No. 2
Control method for specific operations
ON
Control by serial communication commands for the
following operations
• Laser pumping (LSR)
• Shutter control (SHT)
• Guide laser (GID)
• Laser check radiation (SPT)
• Laser power measurement (PWM)
• Test marking (TST)
OFF (initial setting)
Control by I/O for the following operations
• Laser pumping
• Shutter control
• Guide laser
ンㄆㄇㄆㄓㄆㄏㄆ
• “Laser check radiation”, “Laser power measurement” and “Test marking” cannot be controlled by I/O. They can be
controlled only by using serial communication in the remote mode.
ME-LPM-SSM-10
Содержание LP-M Series
Страница 16: ...16 MEMO ME LPM SSM 10...
Страница 27: ...27 Chapter 1 Specification ME LPM SSM 10...
Страница 37: ...37 Chapter 2 Preparation ME LPM SSM 10...
Страница 69: ...Chapter 3 Connection for External Control ME LPM SSM 10...
Страница 128: ...Chapter 4 Maintenance ME LPM SSM 10...
Страница 148: ...Troubleshooting ME LPM SSM 10...
Страница 169: ...Index ME LPM SSM 10...
Страница 172: ...172 MEMO No 9000 0066 34V ME LPM SSM 10...
Страница 173: ...No 9000 0066 34V...