38
2-3-3 Marking field and marking center position
Specified point
LP-GS051
LP-GS051-L
LP-GS052
A : Work distance
Base position
111 mm
71 mm
Setting range *1
108 mm to 114 mm
–
69.5 mm to 72.5 mm
B : Marking field (X, Y)
55 mm × 55 mm
30 mm × 30 mm
C : Distance to center of marking field
54 mm
50.5 mm
*1 : For models without “-L” in the model code, the work distance (Z-position) may be changed within the extent indicated
in this table.
B
A
B
C
139
Unit: mm
Marking
center
Diameter of laser
output range
φ
66
ワㄐㄕㄊㄆ
• Do not place anything in the area between the laser emission port and work pieces during the lasing operation.
• Use anti-reflection material (ex. black paint for metal) for an external shutter or a protective enclosure in a path of laser
beam. It may cause a failure of the components inside the laser marker head.
• If any other devices such as a sensor or a camera are installed near the laser marker, make sure that these devices are
installed in the place where laser beam and its reflected beam do not damage to them.
ME-LPGS-SM-8
Содержание LP-GS Series
Страница 17: ...1 Product Overview ME LPGS SM 8 ...
Страница 32: ...2 Laser Marker Installation ME LPGS SM 8 ...
Страница 48: ...3 Operation Method ME LPGS SM 8 ...
Страница 68: ...4 External Control Using I O ME LPGS SM 8 ...
Страница 107: ...5 External Control by Communication Commands ME LPGS SM 8 ...
Страница 116: ...6 Link Control with External Devices ME LPGS SM 8 ...
Страница 141: ...7 Maintenance ME LPGS SM 8 ...
Страница 161: ...161 MEMO ME LPGS SM 8 ...
Страница 162: ...Troubleshooting ME LPGS SM 8 ...
Страница 186: ...Index ME LPGS SM 8 ...
Страница 188: ...188 Unit power cable 26 USB 30 45 V Vibration resistance 33 W Warning 177 Z Z axis adjustment module 154 ME LPGS SM 8 ...
Страница 189: ......