98
8.2
Reading Specifications
8.2.1 Field of View (Regular Type)
Unit: mm
Distance L
70
80
90
100
110
120
130
140
150
Hosizontal
38
44
49
54
59
64
69
74
79
Vertical
29
33
36
40
44
48
52
56
60
8.2.2 Reading Range (Regular type)
Code
Cell Size
Proximal
Distal
Data Matrix
0.167
85
125
0.25
70
150
QR Code
0.167
85
125
0.25
70
150
Unit: mm
Cell size 0.25 mm or bigger is recommended at the use of Symbol Printing Check.
Reference of distance: Centering around the reading window (Surface)
L
V
ert
ic
al