88
Timing chart for serial data marking
The timing chart for the command for serial data input (SIN) of RS-232C/Ethernet is shown below.
%01:S0, %01:S1 (example when serial data number 0 and 1 are set)
OFF
ON
ON
ON
ON
OFF
OFF
OFF
SINS00
SINS01
SINS00
SINS01
ACK
ACK
ACK
ACK
ON
OFF
T2
T1
LASER IN
SHUTTER
CONTROL
INPUT
TRIG. IN
READY
MARKING
Command data
Response data
(Open)
(Close)
Item
Time
Remarks
T1
1 second or more
SIN command cannot be sent until the shutter opens.
The shutter opens approx. 1 second after the shutter open input.
T2
0 ms or more
After confirming the marking output is turned ON, the next SIN command data can be
sent.
Reference
•
The command for serial data input (SIN) can be transmitted to the laser marker only under remote mode, and when the
internal shutter is opened (“Reception mode ON” is not set for command reception mode (MKM command)).
•
Whenever marking is performed, data of all set serial data function numbers must be transmitted.
ME-LP400V-EX-6
Содержание LP-400 Series
Страница 12: ...1 Before External Control ME LP400V EX 6...
Страница 24: ...2 Control by I O ME LP400V EX 6...
Страница 56: ...3 Control by Serial Communication RS 232 Ethernet ME LP400V EX 6...
Страница 141: ...Troubleshooting ME LP400V EX 6...
Страница 158: ...Character Code Table ME LP400V EX 6...
Страница 166: ...166 Shift JIS JIS 0 1 2 3 4 5 6 7 8 9 A B C D E F 983F 4F20 984F 4F30 985F 4F40 986F 4F50 ME LP400V EX 6...
Страница 176: ...Index ME LP400V EX 6...
Страница 179: ...No 9000 0062 17V...
Страница 180: ...Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 17V...