71
⿎
Readout data format
Start code
Single character
Command
Three characters
Sub command
Single character
Data
Variable length
Check sum
Two characters
Delimiter
Two characters/
single character
Head
End
Code
Description
Start code
A start code is a code to identify the data head. STX (code:02(HEX)) fixed.
Command
A command is specified with three characters. Refer to “3-6 Communication Command List” (P.74).
Sub command
A sub command is an instruction of setting/readout complementary added to a command.
Specifies one of the characters below.
“S”: Data setting or operation (Set)
“R”: Readout of setting data (Read)
(Note) “S” or “R” cannot be selected for some commands.
Data
Data specified per command
The content to be specified varies per command. Refer to “3-7 Command Description” (P.78).
Check sum *1
Check sum indicates the lower 1-byte of adding result of value (binary) from the start code to
the last data by converting it to two characters by ASCII code.
Ex. when the command is “ABC”, sub command is “A” and data is “000”:
02(HEX)+41(HEX)+42(HEX)+43(HEX)+41(HEX)+30(HEX)+30(HEX)+30(HEX)=199(HEX)
99(HEX), the lower 1-byte of 199(HEX) is converted to 39(HEX)+39(HEX), to two characters
by ASCII code.
ON/OFF of check sum can be selected on the environment setting of laser marker.
Refer to the Operation/Maintenance Manual for the details.
Delimiter *2
Delimiter is a code to identify the end of data.
CR+LF (0D(HEX) 0A(HEX)) or CR(0D(HEX)).
Selects CR+LF or CR on the console. Refer to the Operation/Maintenance Manual for the
details.
*1 : A check sum can be added in case of RS-232C.
*2 :
You can select [CR] or [CR+LF] for a delimiter in case of RS-232C. [CR] is fixed in case of Ethernet.
ME-LP400V-EX-6
Содержание LP-400 Series
Страница 12: ...1 Before External Control ME LP400V EX 6...
Страница 24: ...2 Control by I O ME LP400V EX 6...
Страница 56: ...3 Control by Serial Communication RS 232 Ethernet ME LP400V EX 6...
Страница 141: ...Troubleshooting ME LP400V EX 6...
Страница 158: ...Character Code Table ME LP400V EX 6...
Страница 166: ...166 Shift JIS JIS 0 1 2 3 4 5 6 7 8 9 A B C D E F 983F 4F20 984F 4F30 985F 4F40 986F 4F50 ME LP400V EX 6...
Страница 176: ...Index ME LP400V EX 6...
Страница 179: ...No 9000 0062 17V...
Страница 180: ...Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 17V...