64
3-4 Control Sample
This paragraph gives the sample of flow chart for control of laser marker by serial communication.
Change setting contents
1. Laser pumping (ON)
LSR command
Remote mode OFF
2. Marking character string setting
MCS command or STR command
3. General condition setting
ALC command
4. Character condition setting
STC command
5. Laser power setting
LPW command
6. Scan speed setting
SSP command
7. Shutter (open) setting
SHT command
8. Status request
STS command
10. Command reception mode ON MKM command
11. Various conditions setting
Various command
12. Command reception mode OFF MKM command
13. Shutter setting (close)
SHT command
14. Laser pumping (OFF)
LSR command
When “10. Command reception
mode ON” is transmitted, the
commands unacceptable during
shutter open become settable
and various conditions can be set.
After setting various conditions,
set marking ready ON by “12.
Command reception mode OFF”.
The interval between “1 Laser
pumping ON” and “9 Marking
trigger” should be about 20
seconds or more with the LP-V
series, and about 15 seconds
or more with the LP-400 and
LP-W series.
Send STS command
again after a while.
“READY”: ON
Yes
To finish the marking
To change the settings
No.
Remote mode ON
9. Marking trigger
MRK command
ME-LP400V-EX-6
Содержание LP-400 Series
Страница 12: ...1 Before External Control ME LP400V EX 6...
Страница 24: ...2 Control by I O ME LP400V EX 6...
Страница 56: ...3 Control by Serial Communication RS 232 Ethernet ME LP400V EX 6...
Страница 141: ...Troubleshooting ME LP400V EX 6...
Страница 158: ...Character Code Table ME LP400V EX 6...
Страница 166: ...166 Shift JIS JIS 0 1 2 3 4 5 6 7 8 9 A B C D E F 983F 4F20 984F 4F30 985F 4F40 986F 4F50 ME LP400V EX 6...
Страница 176: ...Index ME LP400V EX 6...
Страница 179: ...No 9000 0062 17V...
Страница 180: ...Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 17V...