122
⿎
Character condition : STC
Sets the condition for marking character string per line.
•
Setting / Readout data of character condition
STX
STC
Sub
command
[Character condition No.] [Area No.] [Start line] [End line]
[Marking shape] [Vary with the marking shape]
[Font No.] [Bold line width] [Laser power correction]
[Scan speed correction] [Laser pulse cycle correction]
Max. 83-byte (LP-V series),
Max. 80-byte (LP-400/LP-W series)
(Check
sum)
Delimiter
Sub command is “S” at the time of setting and “A” for response data at the time of readout.
•
Readout request of character condition
STX
STC
R
[Character condition No.]
2-byte
(Check
sum)
Delimiter
1. When marking shape is straight line/proportional/justify
Data length : 75-byte (LP-V series), 72-byte (LP-400/LP-W series)
Name
Data
length
[byte]
Description
Remarks
Character
condition No.
2
“01”–“60”
Area No.
1
“0”–“9”, “A”–“F”
Specifies which area part is the marking
position of the concatenated marking on the
flying object.
In case of marking static object, specify “0”.
Start line
2
“01”–“60” [row]
(“51”–“60”: common setting lines)
The start/end line of character string for
marking with this condition is indicated.
End line
2
Marking
shape
1
“0”: straight line
“1”: Proportional
“2”: Justify
Alignment
1
“0”: left
“1”: center
“2”: right
Character
height
7
Model type*
Setting range [mm]
LP-V10
“000.100”–“090.000”
LP-4x0
“000.100”–“110.000”
LP-4x5/LP-V15
“000.100”–“160.000”
LP-4x1/LP-W
“000.100”–“055.000”
Character
width
7
X position
8
Model type*
Setting range [mm]
LP-V10
“-045.000”–“+045.000”
LP-4x0
“-055.000”–“+055.000”
LP-4x5/LP-V15
“-080.000”–“+080.000”
LP-4x1/LP-W
“-027.500”–“+027.500”
Sets the coordinate (X/Y) of the character.
The base position of the coordinate varies
from “alignment” setting:
Left: lower left of the first character
Center: the center of the string
Right: lower right of the last character
Y position
8
ME-LP400V-EX-6
Содержание LP-400 Series
Страница 12: ...1 Before External Control ME LP400V EX 6...
Страница 24: ...2 Control by I O ME LP400V EX 6...
Страница 56: ...3 Control by Serial Communication RS 232 Ethernet ME LP400V EX 6...
Страница 141: ...Troubleshooting ME LP400V EX 6...
Страница 158: ...Character Code Table ME LP400V EX 6...
Страница 166: ...166 Shift JIS JIS 0 1 2 3 4 5 6 7 8 9 A B C D E F 983F 4F20 984F 4F30 985F 4F40 986F 4F50 ME LP400V EX 6...
Страница 176: ...Index ME LP400V EX 6...
Страница 179: ...No 9000 0062 17V...
Страница 180: ...Panasonic Industrial Devices SUNX Co Ltd 2003 2018 July 2018 9000 0062 17V...