132
Others
Errors and warnings
List of warning codes
Code
notification
SNMP trap
notification
Action to be taken
E3031
±
±
Failed recording due to multiple factors of the drive system and a
magazine. Recording to the magazine is disabled.
)
Check if any problems with the drive system and the magazine
have been detected in the log. If a problem has been detected,
follow the solution for the corresponding error or warning code.
E3040
±
±
Failed read operation in the drive system. There is an abnormality
in the media in the magazine or a failure of the drive or peripheral
circuits of the drive.
)
Try another magazine. If the system detects the same error, it
needs to be repaired.
)
For information on the conditions that cause the error, refer to
Code
notification
SNMP trap
notification
Action to be taken
W1000
±
±
A fault has been detected in the external power supply. The
redundancy of the external power supply has decreased.
)
Replace the external power supply with reference to the manual
for the external power supply in use.
W1001
±
±
A fault has been detected in the normal fan on the back of the unit
or the peripheral circuit of the fan. The operation has been switched
to the redundant fan.
It needs to be repaired.
W1002
±
±
A fault has been detected in the redundant fan on the back of the
unit or the peripheral circuit of the redundant fan.
If the internal temperature is normal, operations will continue.
It needs to be repaired.
W1010
±
±
The software update has failed.
)
Refer “Software problems” (
122) to take proper action.
W1020
±
±
An abnormality has been detected in the panel or the peripheral
circuit of the panel.
)
Turn the unit off and back on.
If the problem persist, contact your support service provider.
(
W1030
s
±
Email submission to the SMTP server has failed.
)
Check if the network setting for the SMTP server is correct.
)
Refer “Network” (
125) to take proper action.