Installation
28
Installing the Appliance
Installation Location
Electrical Work
Dedicated
circuit
• Single-phase 220 V/20 A
(with a circuit breaker)
•
Electric wire for house wiring
: Single wire of at least 2.0 mm in diameter
* Stranded wire of at least 3.5 mm
2
can also be used for the wall socket
(box type).
Earth leakage
circuit breaker
•
Rated current
: 20 A
•
Rated sensitivity current
: 30 mA
* In accordance with the electrical wiring rules, incorporate the breaker and the
earth leakage circuit breaker in the home electrical wire.
Wall socket
•
Type of socket
:
BS1363 type
•
Installation location
Built-in
• Observe related
laws for installation.
Built-in
Free-standing
To the ceiling
To the ceiling
Wall and ceiling
Minimum clearance
(unit: cm)
Minimum clearance
(unit: cm)
Incombustible*
1
0
70
0
1*
2
70
0
Combustible
5
100
5
5
100
5
*1 Metal, tile, brick, etc. (Including heat-insulating board made of metal, tile, brick, etc.)
*2 An exhaust vent is provided on the back of the appliance.
• Follow the local safety laws
and regulations for electrical
wiring and earthing applied
in the area.
• Do not twist or load on the
power cord.
Free-standing
●
Do not place.
Paper or sheet
Free-standing
Built-in
1
2
3
Insert horizontally.
Insert the plug to the socket.
Make sure there is no space between the countertop
and the top plate in the front, back, left and right.
Power cord
●
Do not drop.
Install the socket where the plug can be
disconnected.
WARNING
• Provide socket wiring
for single-pole earthing.