Value Range
0–6
–
0: Sunday
–
1: Monday
–
2: Tuesday
–
3: Wednesday
–
4: Thursday
–
5: Friday
–
6: Saturday
Default Value
0
DST_STOP_TIME
Value Format
Integer
Description
Specifies the end time of DST (Summer Time) in minutes after 12:00
AM.
Note
•
This parameter is disabled when the
"
LOCAL_TIME_ZONE_POSIX
" parameter is specified.
Value Range
0–1439
Default Value
120
LOCAL_TIME_ZONE_POSIX
Value Format
String
Description
Specifies a IEEE 1003.1 (POSIX)-compliant local time zone definition
(e.g., "EST+5:00:00EDT+4:00:00,M4.1.0/2:00:00,M10.5.0/2:00:00").
Note
•
If this parameter is specified, the following parameters are
disabled, and operation will be based on this parameter.
–
TIME_ZONE
–
DST_ENABLE
–
DST_OFFSET
–
DST_START_MONTH
–
DST_START_ORDINAL_DAY
–
DST_START_DAY_OF_WEEK
–
DST_START_TIME
–
DST_STOP_MONTH
–
DST_STOP_ORDINAL_DAY
–
DST_STOP_DAY_OF_WEEK
–
DST_STOP_TIME
Value Range
Max. 70 characters
Default Value
Empty string
172
Administrator Guide
Document Version 2013-03
4.2.2 System Time Settings
Содержание KX-UDS124
Страница 146: ...146 Administrator Guide Document Version 2013 03 2 7 7 Restart ...
Страница 164: ...164 Administrator Guide Document Version 2013 03 3 5 2 Example with Incorrect Descriptions ...
Страница 250: ...250 Administrator Guide Document Version 2013 03 5 2 PS Registration using Provisioning ...
Страница 274: ...274 Administrator Guide Document Version 2013 03 8 1 How to back up and restore configuration data ...
Страница 280: ...280 Administrator Guide Document Version 2013 03 10 1 Troubleshooting ...
Страница 281: ...Section 11 Appendix Document Version 2013 03 Administrator Guide 281 ...
Страница 286: ...286 Administrator Guide Document Version 2013 03 11 1 Open Source Software ...
Страница 287: ...Index Document Version 2013 03 Administrator Guide 287 ...
Страница 289: ...Document Version 2013 03 Administrator Guide 289 Notes ...
Страница 290: ...290 Administrator Guide Document Version 2013 03 Notes ...
Страница 291: ...Document Version 2013 03 Administrator Guide 291 Notes ...