2.6 Hardware (H/W) Settings
Programming Guide
147
Number of Glitch
Specifies the number of glitch that the VPS interpret Off-hook detection after a call is dialled.
Value Range
0–5 times
Glitch Time
Specifies the length of signal to be interpreted as glitch by the VPS after a call is dialled.
Value Range
40 ms–100 ms
Unique Cyclic Tone Detection
Specifies whether the VPS detects unique cyclic tones and interprets them as the end of a call.
Value Range
Disable, Enable
Silence Detection for Off-hook Detection
Specifies whether the VPS interprets silence detection as off-hook detection. If there is a long period
of silence after a call is dialled, select "Disable" to prevent the VPS from detecting the silence as an
off-hook signal.
Value Range
Disable, Enable
CNG Detection Sensitivity
Specifies CNG detection sensitivity.
Value Range
-53– -43 dBm
VOX Detection Sensitivity
Specifies VOX detection sensitivity.
Value Range
-55– -25 dBm
Содержание KX-TVM50
Страница 33: ...2 1 Mailbox Settings Programming Guide 33 Feature Guide References 2 5 2 Default Mailbox Template ...
Страница 51: ...2 1 Mailbox Settings Programming Guide 51 Subscriber s Guide References 5 6 Personal Group Distribution Lists ...
Страница 98: ...2 4 Service Settings 98 Programming Guide Feature Guide References 2 3 15 Custom Service ...
Страница 158: ...2 7 Reports 158 Programming Guide Feature Guide References 2 5 6 System Reports ...
Страница 168: ...2 7 Reports 168 Programming Guide Feature Guide References 2 5 6 System Reports ...
Страница 180: ...2 8 System Security 180 Programming Guide ...
Страница 193: ...Programming Guide 193 Index ...
Страница 199: ...Index Programming Guide 199 ...