Value Format
BOOLEAN
Description
Specifies whether to enable sending a REGISTER request to the SIP
server after receiving 403 error in response to an INVITE request.
Value Range
•
Y
: Enable
•
N
: Disable
Default Value
Y
ESCAPECODE_CONVERSION_RFC3986
Value Format
BOOLEAN
Description
Specifies whether to comply with RFC2396 or RFC3986 for reserved
characters.
Value Range
•
Y
: RFC3986 compliant
•
N
: RFC2396 compliant
Default Value
N
ENH_FOVR_RESPONSE_CODE
Value Format
STRING
Description
Specifies the error code for failover.
Note
•
The available error codes are: 403, 404, 406, 408, 480, 488,
500, 502, 503, 504, 600, 603, 604, 606
Example: ENH_FOVR_RESPONSE_CODE="408, 603"
Value Range
Max. 256 characters
Default Value
Empty string
ENH_FOVR_REGISTER_ENABLE_n
For details about parameter names that include lower-case letters (e.g., "_n", "y", "x", or "m"), see
"4.2.1 Configuration File Parameters".
Value Format
BOOLEAN
Description
Specifies whether to enable failover when the response to a
REGISTER request is the error code set for
ENH_FOVR_RESPONSE_CODE.
Value Range
•
Y
: Enable
•
N
: Disable
Default Value
Y
ENH_FOVR_INVITE_ENABLE_n
For details about parameter names that include lower-case letters (e.g., "_n", "y", "x", or "m"), see
"4.2.1 Configuration File Parameters".
Value Format
BOOLEAN
4.24 SIP Settings
Document Version: 2020-04
Administrator Guide
285
Содержание KX-TGP700
Страница 8: ...Table of Contents 8 Administrator Guide Document Version 2020 04 ...
Страница 158: ...3 7 9 Call Status Monitoring 158 Administrator Guide Document Version 2020 04 ...
Страница 388: ...5 7 Flexible Key Setting for KX TPA68 388 Administrator Guide Document Version 2020 04 ...
Страница 399: ...Panasonic Corporation 1006 Oaza Kadoma Kadoma shi Osaka 571 8501 Japan Panasonic Corporation 2020 PNQX8943ZA PP0420SM0 ...