Value Range
0–5000 (0: Infinite time)
Note
•
The unit will play the tone for the duration of the first value, stop
it for the duration of the second value, play it for the duration of
the third value, and then stop it for the duration of the last value.
The whole sequence will then repeat. For example, if the value
for this setting is "100,100,0,0", the unit will play the tone for 100
ms, stop it for 100 ms, and then play it continuously.
Default Value
0,0,0,0 (The unit plays the dial tone continuously.)
Configuration File Reference
3.7.4.2 Busy Tone
Tone Frequencies
Description
Specifies the dual-tone frequencies, in hertz, of busy tones using 2
whole numbers separated by a comma.
Value Range
0, 200–1000 (0: No tone)
Default Value
480,620
Configuration File Reference
Tone Timings
Description
Specifies the pattern, in milliseconds, of busy tones using 4 whole
numbers (on 1, off 1, on 2, off 2) separated by commas.
Value Range
0–5000 (0: Infinite time)
Default Value
500,500,500,500
Configuration File Reference
3.7.4.3 Ringing Tone
Tone Frequencies
Description
Specifies the dual-tone frequencies, in hertz, of ringback tones using 2
whole numbers separated by a comma.
Value Range
0, 200–1000 (0: No tone)
Default Value
440,480
Configuration File Reference
Document Version 2013-02
Administrator Guide
119
3.7.4 Tone Settings
Содержание KX-TGP500
Страница 224: ...224 Administrator Guide Document Version 2013 02 4 8 Setting Configuration File Parameters Using TR 069 ...
Страница 238: ...238 Administrator Guide Document Version 2013 02 5 3 1 Dial Plan Settings ...
Страница 242: ...242 Administrator Guide Document Version 2013 02 6 4 Local Firmware Update ...
Страница 264: ...264 Administrator Guide Document Version 2013 02 8 3 Example with Incorrect Descriptions ...
Страница 272: ...272 Administrator Guide Document Version 2013 02 ...
Страница 273: ...Section 10 Appendix Document Version 2013 02 Administrator Guide 273 ...
Страница 277: ...Index Document Version 2013 02 Administrator Guide 277 ...