background image

© Panasonic Corporation 2018 
Unauthorized copying and distribution is a violation 
of law.

ORDER NO. KM41712123CE

F13

HD Link2Cell Cordless Telephone with Digital Answering Machine

Model No.

KX-TGE674
KX-TGEA61

B: Black Version 

Model No.

Base Unit

 

Handset 

Charger Unit

 

 

Configuration for each model

KX-TGE674
KX-TGEA61

1(TGE670) 4(TGEA61)

1(TGEA61)

Expandable

Up to 6

*KX-TGEA61 is also an optional accessory, which contains a 
 handset and a charger.

3
1

KX-TGEA61

(Handset)

KX-TGE670

(Base Unit)

(Charger Unit)

Содержание KX-TGE674

Страница 1: ...e with Digital Answering Machine Model No KX TGE674 KX TGEA61 B Black Version Model No Base Unit Handset Charger Unit Configuration for each model KX TGE674 KX TGEA61 1 TGE670 4 TGEA61 1 TGEA61 Expandable Up to 6 KX TGEA61 is also an optional accessory which contains a handset and a charger 3 1 KX TGEA61 Handset KX TGE670 Base Unit Charger Unit ...

Страница 2: ... Circuit Board Diagrams Exploded Views and Replacement Parts List It is essential that these critical parts should be replaced with manufacturer s specified parts to prevent shock fire or other hazards Do not modify the original design without permission of manufacturer IMPORTANT INFORMATION ABOUT LEAD FREE PbF SOLDERING If lead free solder was used in the manufacture of this product the printed c...

Страница 3: ...mat on worktable 4 Do not touch the IC or LSI pins with bare fingers 2 Warning 2 1 Battery Caution Risk of explosion if battery is replaced by an incorrect type Dispose of used batteries according to the instructions Attention A nickel metal hydride battery that is recyclable powers the product you have purchased Please call 1 800 8 BATTERY 1 800 822 8837 for information on how to recycle this bat...

Страница 4: ...1 Unplug the AC inlet and connect the two prongs of the plug with a jumper wire 2 Measure the resistance value with ohmmeter between the jumpered AC plug and all the terminals as shown in following figures 3 If the measurement is outside the specified limits there is a possibility of shock hazard The equipment should be repaired and rechecked before it is returned to the customer 2 4 Discarding of...

Страница 5: ...le SPP Message Access Profile MAP Frequency range 1 92 GHz to 1 93 GHz DECT 2 402 GHz to 2 48 GHz Bluetooth RF transmission power 115 mW max Power source 120 V AC 60 Hz Power consumption Base unit Standby 1 2 W Maximum 4 5 W Charger Standby 0 1 W Maximum 1 8 W Operating conditions 0 C 40 C 32 F 104 F 20 80 relative air humidity dry Dimension H x W x D Base unit Approx 61 mm x 197 mm x 99 mm Handse...

Страница 6: ...ructions Instruction book on TSN Server 5 Installation Instructions Refer to the Operating Instructions Note You can download and refer to the Operating Instructions Instruction book on TSN Server 6 Operating Instructions Refer to the Operating Instructions Note You can download and refer to the Operating Instructions Instruction book on TSN Server ...

Страница 7: ...time with the development of new technology 7 1 2 Handset Schematic Diagram Handset_Main Notes 1 DC voltage measurements are taken with an oscilloscope or a tester with a ground 2 The schematic diagrams may be modified at any time with the development of new technology Important Safety Notice Components identified by mark have special characteristics important for safety When replacing any of thes...

Страница 8: ...NDplane3 102 VSS GNDplane4 103 VSS GNDplane5 104 VSS GNDplane6 105 VSS GNDplane7 106 VSS GNDplane8 112 VSS GNDplane9 113 VSS GNDplane10 118 ULP_PORT 116 ULP_VBAT 117 ULP_XTAL 110 VBAT 131 VSS GNDplane15 128 VSS GNDplane14 127 VSS GNDplane13 124 VSS GNDplane12 114 VSS GNDplane11 132 VSS GNDplane16 C174 2200p C164 NC RA451 2 2k 1 2 3 4 RA452 2 7k 1 2 3 4 5 5V Q353 Q352 C352 NC CHG Q351 C103 0 01u C1...

Страница 9: ...KEYIN3 KEYS_B KEYS_A KEYS_C KEYIN4 KEYIN1 KEYIN5 KEYIN6 KEYS_D KEYS_E LED_VDD MIC 1 2 CELL1_LED LED903 RED A K LED904 GREEN A K LED905 GREEN A K DA901 1 RESET 2 SDA 4 GND 5 SCL 3 VDD ASSIST 1 2 HS_LOCAT 1 2 DOWN 1 2 UP 1 2 ERASE MUTE 1 2 RPT 1 2 SKIP 1 2 PLAY STOP 1 2 1 2 1 2 ANS 1 2 1 2 1 2 1 2 1 2 3 2 1 2 1 2 1 1 2 1 1 2 1 2 2 1 2 1 2 1 2 4 7 5 8 0 9 6 1 1 2 1 2 2 1 1 2 2 HOLD SP PHONE FLASH RED...

Страница 10: ...V C3 VDD_PADS C4 VSS_DIG A1 VSS_AUX C1 VSS_RADIO A6 UART_TX B5 UART_RX C5 UART_CTS B6 UART_RTS D2 PCM_SYNC SPI_CS D3 PCM_CLK SPI_CLK E6 SPI_ PCM_SEL D5 PIO2 E3 PIO3 C2 VDD_AUX B1 BT_RF A3 SYS_CLK XTAL_IN A2 XTAL_OUT E2 PCM_OUT SPI_MISO D4 PCM_IN SPI_MOSI E1 PIO0 B2 VDD_RADIO D6 VDD_DIG E4 PIO1 IC2 J3 VSS7 L6 VSS8 L2 C L4 VSS9 K1 VCC2 L3 P46 X0A K3 P47 X1A K4 INITX J5 P48 K6 P49 J6 P4A L7 P4B K7 P4...

Страница 11: ... VG LCD 5 A0 1 8V C82 NC GNDA C84 NC C87 K1000p C83 NC GND C39 K1000p R91 10 GND R500 NC GNDA R34 100k R32 100k GND C33 K0 1u C94 K0 1u RA3 680 1 4 2 RA2 680 8 2 3 4 L9 GND CP3V 1 8V POWER CARBON_CL1 C120 NC C15 J68p GND C121 J68p GND C122 J68p GND C123 J68p C124 J68p C125 J68p GND GND VOL_DOWN VOL_UP D1 NC D2 NC GND GND GND D3 NC GND D4 NC GNDA GNDA C16 10uF SOFT_C SOFT_A RIGHT UP DOWN LEFT 1 SHA...

Страница 12: ...6 BAT VBAT2 47 LED1 48 GND_18 49 GND_4 50 BELL_LED2 51 GND_19 52 P2_3 53 STB_D 54 STB_C 55 GND_20 56 MIC 57 GNDA 58 BAT VBAT1 59 CP3V 60 GND_21 61 GND_22 62 GND_23 63 LCD_CD 64 LCD_CS 65 STB_A 66 KIN_5 67 KIN_4 68 KIN_1 69 GND_24 70 GND_25 71 GND_26 HEADSET_DET C13 0 1uF C11 0 1uF C70 NC C71 1000pF GNDA GNDA IC1 3 RFP1 4 RFP0 5 REF_RES 6 AVS_XTAL 7 XTAL2 8 XTAL1 9 AVD_XTAL 10 RF_SUPPLY1 11 PARADET...

Страница 13: ...ok on TSN Server SH KX TGE674B Safety Ref No Part No Part Name Description Remarks A1 PNLV226 0X AC ADAPTOR FOR BASE UNIT A2 PNJA1186Z CORD TELEPHONE A3 PNKE2125Z1 HANGER BELT CLIP ABS HB A4 PNKL1001X1 WALL MOUNT ADAPTOR PS HB A5 PNLC1079ZB CHARGER UNIT A5 1 PNLV233 AX AC ADAPTOR FOR CHARGER UNIT A6 PNKK1147Z1 LID BATTERY ABS HB A7 PNHS1691Z SPACER BATTERY A8 PNYNTGEA60BR LID BATTERY ASS Y A9 PNQW...